OSHA SearchOSHA records by employer

Dubworks SC, LLC: OSHA inspections and violations

Pueblo, Colorado · Custom Architectural Woodwork and Millwork Manufacturing · NAICS 337212

3inspections
9citation items
$12,719current penalties
Jul 11, 2017last inspection

OSHA has inspected Dubworks SC, LLC 3 times in Colorado since 2017.

The latest one began on Jul 11, 2017 to follow up on an earlier case, in Pueblo.

Those inspections ended with 9 citation items: 5 serious and 4 other-than-serious.

Penalties were first proposed at $12,719 and still stand at $12,719.

Woodworking machinery comes up most often in these citations: 2 items under 1910.213.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dubworks SC, LLC averages $6,360 (2 cited inspections).

Dubworks SC, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

130employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Dubworks SC, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342486172 OPENED JUL 11, 2017Closed

Follow-up · No inspection · Health · 1 employee at the site · Closed Jul 11, 2017

205 North Elizabeth St, Suite C, Pueblo, CO 81003 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342040755 OPENED JAN 17, 2017Closed

Referral · Partial · Health · Local government · 21 employees at the site · Closed Apr 7, 2020

205 North Elizabeth St, Suite C, Pueblo, CO 81003 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$2,173$2,173Mar 30, 2017Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,173$2,173Mar 30, 2017Final
Citation 2, item 1
29 CFR 1910.94(c)(2) · Ventilation
Other-than-serious$0$0Mar 30, 2017Final

Inspection 342017688 OPENED JAN 6, 2017Closed

Complaint · Complete · Safety · 21 employees at the site · Closed Aug 15, 2019

205 North Elizabeth St, Suite C, Pueblo, CO 81003 · Custom Architectural Woodwork and Millwork Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$2,897$2,897Mar 30, 2017Final
Citation 1, item 2a
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$5,070$5,070Mar 30, 2017Final
Citation 1, item 2b
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Mar 30, 2017Final
Citation 2, item 1a
29 CFR 1910.22(a)(1) · Walking-working surfaces
Other-than-serious$406$406Mar 30, 2017Final
Citation 2, item 1b
29 CFR 1910.37(a)(3) · Exit routes
Other-than-serious$0$0Mar 30, 2017Final
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 30, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(2)

(2) Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.37 · Exit routes

29 CFR 1910.94 · Ventilation

Other custom architectural woodwork and millwork manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.