OSHA SearchOSHA records by employer

Duris Electro Plating Inc: OSHA inspections and violations

Springville, Utah · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

2inspections
5citation items
$2,250current penalties
Mar 7, 2017last inspection

Duris Electro Plating Inc has 2 OSHA inspections on record in Utah, the first in 2017.

OSHA's last visit started on Mar 7, 2017 after a complaint, in Springville, and the case has not closed yet.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $4,500 in penalties. After settlements and reviews the total is $2,250, down 50%.

Most often, OSHA cited 1910.132, personal protective equipment, general requirements (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Duris Electro Plating Inc averages $2,250 over 1 cited inspection in that time.

Duris Electro Plating Inc: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Duris Electro Plating Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342153509 OPENED MAR 7, 2017Open

Complaint · Partial · Safety · 10 employees at the site · Open

657 W. 1300 N. #300, Springville, UT 84663 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 342091873 OPENED FEB 8, 2017Closed

Planned · Partial · Safety · 10 employees at the site · Closed May 16, 2017

657 W. 1300 N., Springville, UT 84663 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements
Serious$1,500$750Mar 15, 2017Final
Citation 1, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,500$750Mar 15, 2017Final
Citation 1, item 2b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Mar 15, 2017Final
Citation 1, item 3a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$1,500$750Mar 15, 2017Final
Citation 1, item 3b
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$0$0Mar 15, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.303 · Electrical equipment, general requirements

Other electroplating, plating, polishing, anodizing, and coloring employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.