Inspection 345161590 OPENED FEB 23, 2021Closed
307 West Lucas Street, Florence, SC 29501 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Florence, South Carolina · Recyclable Material Merchant Wholesalers · NAICS 423930
OSHA has inspected Dutton Polymer Group LLC 2 times in South Carolina since 2021.
The latest one began on Feb 23, 2021 after a complaint, in Florence.
Those inspections ended with 3 citation items: 2 serious and 1 other-than-serious.
Penalties were first proposed at $2,850 and still stand at $2,850.
How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Dutton Polymer Group LLC averages $2,850 (1 cited inspection).
Want to know if OSHA cites Dutton Polymer Group LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company307 West Lucas Street, Florence, SC 29501 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
307 West Lucas Street, Florence, SC 29501 · Recyclable Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.141(a)(3)(ii) · Sanitation |
Serious | $1,050 | $1,050 | Jul 15, 2021 | Final |
| Citation 1, item 2 29 CFR 1910.165(d)(1) · Employee alarm systems |
Serious | $1,500 | $1,500 | Jul 15, 2021 | Final |
| Citation 2, item 1 29 CFR 3.1(A)(2) |
Other-than-serious | $300 | $300 | Jul 15, 2021 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.141(a)(3)(ii)
(ii) The floor of every workroom shall be maintained, so far as practicable, in a dry condition. Where wet processes are used, drainage shall be maintained and false floors, platforms, mats, or other dry standing places shall be provided, where practicable, or appropriate waterproof footgear shall be provided.
29 CFR 1910.165(d)(1)
(d) Maintenance and testing. (1) The employer shall assure that all employee alarm systems are maintained in operating condition except when undergoing repairs or maintenance.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.