DVM Utilities Inc: OSHA inspections and violations
Clinton Twp, Michigan · Water and Sewer Line and Related Structures Construction · NAICS 237110
28inspections
34citation items
$7,145current penalties
May 13, 2024last inspection
Since 1989, OSHA inspectors have visited DVM Utilities Inc in Michigan 28 times.
The most recent inspection opened on May 13, 2024 as a planned inspection, in Novi.
In all, OSHA issued 34 citation items: 14 serious and 20 other-than-serious.
The proposed penalties came to $12,295; today they stand at $7,145, 42% less.
The rule cited most here is 4084.933 (), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. DVM Utilities Inc averages $883 across 6 cited inspections.
DVM Utilities Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Michigan · latest 90 days of OSHA records
650employers cited
12 of them in the same industry
Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.
Planned · Complete · Safety · 6 employees at the site · Closed Apr 20, 2004
N Side Of 17 Mile Rd Between Mound & Vandyke, Sterling Hgts, MI 48310 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Sterling Heights site logged 1 recordable injury or illness among about 156 workers: 0.6 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 121 days away from work.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
DVM Utilities Inc
Sterling Heights · 2025
156
1
1
0.6
1.0
D.V.M. Utilities, Inc.
Sterling Heights · 2024
146
2
0
1.4
1.0
DVM Utilities, Inc.
Sterling Heights · 2023
149
4
4
2.6
1.0
Included with any plan: 1 more yearly log from these sites, back to 2022, with each site's average rate over its latest three years. Already a subscriber? Sign in.
(c) Specified exposure control methods. (1) For each employee engaged in a task identified on Table 1, the employer shall fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section.
29 CFR 1926.1153(d)(2)(i)
(2) Exposure assessment—(i) General. The employer shall assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section.
29 CFR 1926.1153(g)(1)
(g) Written exposure control plan. (1) The employer shall establish and implement a written exposure control plan that contains at least the following elements:
29 CFR 1926.1203 · Confined Spaces in Construction: general requirements
Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.