OSHA SearchOSHA records by employer

Dynametal Technologies, Inc.: OSHA inspections and violations

Brownsville, Tennessee · Mechanical Power Transmission Equipment Manufacturing · NAICS 333613

9inspections
72citation items
$26,073current penalties
Apr 11, 2019last inspection

OSHA has inspected Dynametal Technologies, Inc. 9 times in Tennessee since 1998.

The latest one began on Apr 11, 2019 after a complaint, in Brownsville.

Those inspections ended with 72 citation items: 40 serious and 32 other-than-serious.

Penalties were first proposed at $31,850 and now stand at $26,073, 18% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 10 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dynametal Technologies, Inc. averages $7,112 (2 cited inspections).

Dynametal Technologies, Inc.: OSHA citation items per year, 1998 to 2019
Citation items per year, by inspection date.

Tennessee · latest 90 days of OSHA records

349employers cited

Get notified the morning OSHA posts each new citation in Tennessee: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Tennessee

Checking a subcontractor, a client or your own company? Watch Dynametal Technologies, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343928198 OPENED APR 11, 2019Closed

Complaint · Partial · Health · 77 employees at the site · Closed Mar 13, 2020

400 N Dupree Ave, Brownsville, TN 38012 · Powder Metallurgy Part Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.22(a)(1) · Walking-working surfaces
Serious$5,400$4,050Sep 27, 2019Final
Citation 1, item 1b
29 CFR 1910.22(a)(2) · Walking-working surfaces
Serious$0$0Sep 27, 2019Final
Citation 1, item 2a Serious$1,200$900Sep 27, 2019Final
Citation 1, item 2b Serious$0$0Sep 27, 2019Final
Citation 1, item 3a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,050$788Sep 27, 2019Final
Citation 1, item 3b
29 CFR 1910.134(e)(4)(i) · Respiratory protection
Serious$0$0Sep 27, 2019Final
Citation 1, item 3c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 27, 2019Final
Citation 1, item 3d
29 CFR 1910.134(h)(1)(i) · Respiratory protection
Serious$0$0Sep 27, 2019Final
Citation 1, item 3e
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Serious$0$0Sep 27, 2019Final
Citation 1, item 3f
29 CFR 1910.134(l)(1) · Respiratory protection
Serious$0$0Sep 27, 2019Final
Citation 1, item 4a Serious$750$562Sep 27, 2019Final
Citation 1, item 4b
29 CFR 1910.141(g)(2) · Sanitation
Serious$0$0Sep 27, 2019Final
Citation 2, item 1
29 CFR 1910.138(a) · Gloves and hand protection
Other-than-serious$150$112Sep 27, 2019Final
Citation 2, item 2
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$150$113Sep 27, 2019Final
Citation 2, item 3a
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 27, 2019Final
Citation 2, item 3b
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 27, 2019Final
Citation 2, item 4
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$150$113Sep 27, 2019Final
Citation 2, item 5
29 CFR TDLWD RULE 800-01-03-.03(27)(B)1
Other-than-serious$300$225Sep 27, 2019Final

Inspection 343929816 OPENED APR 11, 2019Closed

Complaint · Partial · Safety · 77 employees at the site · Closed Jan 30, 2020

400 N Dupree Ave, Brownsville, TN 38012 · Powder Metallurgy Part Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$900$720Jul 5, 2019Final
Citation 1, item 2
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$900$720Jul 5, 2019Final
Citation 1, item 3
29 CFR 1910.217(c)(2)(i)(a) · Mechanical power presses
Serious$1,750$1,400Jul 5, 2019Final
Citation 1, item 4
29 CFR 1910.217(c)(2)(i)(d) · Mechanical power presses
Serious$1,500$1,200Jul 5, 2019Final
Citation 1, item 5
29 CFR 1910.219(b)(1)(i) · Belts, pulleys and power-transmission parts
Serious$1,500$1,200Jul 5, 2019Final
Citation 1, item 6
29 CFR 1910.219(b)(2) · Belts, pulleys and power-transmission parts
Serious$1,750$1,400Jul 5, 2019Final
Citation 1, item 7
29 CFR 1910.219(h)(1) · Belts, pulleys and power-transmission parts
Serious$900$720Jul 5, 2019Final
Citation 2, item 1
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Other-than-serious$0$0Jul 5, 2019Final
Citation 2, item 2
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Other-than-serious$0$0Jul 5, 2019Final
Citation 2, item 3
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Jul 5, 2019Final
Citation 2, item 4
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jul 5, 2019Final
Citation 2, item 5
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Jul 5, 2019Final
Citation 2, item 6
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$0$0Jul 5, 2019Final

Inspection 317021913 OPENED MAR 8, 2013Closed

Planned · Complete · Safety · 63 employees at the site · Closed Apr 1, 2013

400 Dupree Avenue, Brownsville, TN 38012 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Mar 21, 2013Closed
Citation 1, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 21, 2013Closed
Citation 1, item 3
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Mar 21, 2013Closed

Inspection 313929648 OPENED DEC 15, 2009Closed

Planned · Complete · Safety · 68 employees at the site · Closed Apr 19, 2010

400 North Dupree Avenue, Brownsville, TN 38012 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Serious$800$600Feb 26, 2010Closed
Citation 1, item 2
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$1,000$700Feb 26, 2010Closed
Citation 1, item 3a
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$1,000$700Feb 26, 2010Closed
Citation 1, item 3b
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$0$0Feb 26, 2010Closed
Citation 1, item 3c
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$0$0Feb 26, 2010Closed
Citation 1, item 4
29 CFR 1910.179(g)(2)(ii) · Overhead and gantry cranes
Serious$1,000$750Feb 26, 2010Closed
Citation 2, item 1
29 CFR 1910.22(a)(2) · General requirements
Other-than-serious$100$100Feb 26, 2010Closed
Citation 2, item 2a Other-than-serious$200$100Feb 26, 2010Closed
Citation 2, item 2b Other-than-serious$0$0Feb 26, 2010Closed
Citation 2, item 3
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Other-than-serious$100$100Feb 26, 2010Closed
Citation 2, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$100$100Feb 26, 2010Closed
Citation 2, item 5
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Feb 26, 2010Closed
Citation 2, item 6
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$100$100Feb 26, 2010Closed
Citation 2, item 7
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Other-than-serious$100$100Feb 26, 2010Closed

Inspection 309926087 OPENED MAY 5, 2006Closed

Follow-up · Partial · Safety · 92 employees at the site · Closed May 12, 2006

400 North Dupree Avenue, Brownsville, TN 38012 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309231538 OPENED OCT 24, 2005Closed

Planned · Complete · Safety · 92 employees at the site · Closed May 12, 2006

400 North Dupree Avenue, Brownsville, TN 38012 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$800$800Dec 22, 2005Closed
Citation 1, item 1b
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$0$0Dec 22, 2005Closed
Citation 1, item 2a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$1,200$1,200Dec 22, 2005Closed
Citation 1, item 2b
29 CFR 1910.147(c)(8) · Lockout/tagout
Serious$0$0Dec 22, 2005Closed
Citation 1, item 3a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$1,400$1,400Dec 22, 2005Closed
Citation 1, item 3b
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$0$0Dec 22, 2005Closed
Citation 1, item 4a
29 CFR 1910.305(a)(1)(i) · Electrical wiring methods
Serious$1,200$1,200Dec 22, 2005Closed
Citation 1, item 4b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Dec 22, 2005Closed
Citation 1, item 4c
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Dec 22, 2005Closed
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$200$200Dec 22, 2005Closed
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$100$100Dec 22, 2005Closed

Inspection 306127143 OPENED JAN 14, 2003Closed

Planned · Partial · Safety · 2 employees at the site · Closed May 16, 2003

400 North Dupree Avenue, Brownsville, TN 38012 · Mechanical Power Transmission Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.217(b)(7)(iv) · Mechanical power presses
Serious$2,100$1,600Mar 31, 2003Closed

Inspection 304004773 OPENED FEB 27, 2001Closed

Planned · Complete · Safety · 105 employees at the site · Closed Jun 6, 2001

400 North Dupree Avenue, Brownsville, TN 38012 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$400$400May 9, 2001Closed
Citation 1, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Serious$400$400May 9, 2001Closed
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$300$300May 9, 2001Closed
Citation 2, item 1
29 CFR 1910.253(b)(2)(iv) · Gas welding and cutting
Other-than-serious$0$0May 9, 2001Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0May 9, 2001Closed
1 older inspection

Inspection 120532957 OPENED JUL 29, 1998Closed

Planned · Complete · Health · 107 employees at the site · Closed Dec 28, 1998

400 North Dupree Avenue, Brownsville, TN 38012 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$300$300Dec 8, 1998Closed
Citation 1, item 2
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$300$300Dec 8, 1998Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$100$100Dec 8, 1998Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$100$100Dec 8, 1998Closed
Citation 2, item 3
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0Dec 8, 1998Closed
Citation 2, item 4
29 CFR 1910.133(a)(2) · Eye and face protection
Other-than-serious$0$0Dec 8, 1998Closed
Citation 2, item 5
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$100$100Dec 8, 1998Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.1200(g)(1)

(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other mechanical power transmission equipment manufacturing employers in Tennessee

Alert subscribers get notified of each newly cited employer in Tennessee the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.