Inspection 346876642 OPENED AUG 1, 2023Closed
1105 9 Ne Street, Cape Coral, FL 33904 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Dynasty Building Solutions LLC has 2 OSHA inspections on record in Florida, the first in 2019.
OSHA's last visit started on Aug 1, 2023 as a planned inspection, in Cape Coral.
Across those inspections OSHA issued 6 citation items: 4 serious and 2 other-than-serious.
OSHA proposed $17,238 in penalties. After settlements and reviews the total is $8,619, down 50%.
Most often, OSHA cited 1926.1053, ladders in construction (2 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Dynasty Building Solutions LLC averages $8,619 over 1 cited inspection in that time.
Florida · latest 90 days of OSHA records
320employers cited
69 of them in the same industry
Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Florida
Checking a subcontractor, a client or your own company? Watch Dynasty Building Solutions LLC and get notified the morning OSHA posts a new citation for it.
Watch this company1105 9 Ne Street, Cape Coral, FL 33904 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
12306 Dawn Vista Drive, Riverview, FL 33578 · Roofing Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Serious | $7,956 | $3,978 | Jan 14, 2020 | Final |
| Citation 1, item 2 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $5,304 | $2,652 | Jan 14, 2020 | Final |
| Citation 1, item 3a 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $3,978 | $1,989 | Jan 14, 2020 | Final |
| Citation 1, item 3b 29 CFR 1926.1053(b)(5)(i) · Ladders in construction |
Serious | $0 | $0 | Jan 14, 2020 | Final |
| Citation 2, item 1 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Other-than-serious | $0 | $0 | Jan 14, 2020 | Final |
| Citation 2, item 2 29 CFR 1926.1060(a)(1)(iii) · Ladder and stairway training |
Other-than-serious | $0 | $0 | Jan 14, 2020 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.102(a)(1)
(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(5)(i)
(5)(i) Non-self-supporting ladders shall be used at an angle such that the horizontal distance from the top support to the foot of the ladder is approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).
Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.