OSHA SearchOSHA records by employer

Dynics Inc: OSHA inspections and violations

Ann Arbor, Michigan · Computer Terminal and Other Computer Peripheral Equipment Manufacturing · NAICS 334118

3inspections
10citation items
$3,375current penalties
Sep 29, 2022last inspection

OSHA has inspected Dynics Inc 3 times in Michigan since 2008.

The latest one began on Sep 29, 2022 as part of a related case, in Ann Arbor.

Those inspections ended with 10 citation items: 4 serious and 6 other-than-serious.

Penalties were first proposed at $3,750 and now stand at $3,375, 10% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 2 items under 1910.1200.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Dynics Inc averages $1,500 (2 cited inspections).

Dynics Inc also files yearly injury logs with OSHA, summarized below.

Dynics Inc: OSHA citation items per year, 2008 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Dynics Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346252406 OPENED SEP 29, 2022Closed

Unprogrammed related · Partial · Health · 70 employees at the site · Closed Apr 7, 2023

620 Technology Dr, Ann Arbor, MI 48108 · Computer Terminal and Other Computer Peripheral Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$1,500$1,500Feb 8, 2023Final
Citation 1, item 1b
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$0$0Feb 8, 2023Final
Citation 1, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,500$1,500Feb 8, 2023Final

Inspection 345744890 OPENED JAN 26, 2022Closed

Complaint · Partial · Safety · 67 employees at the site · Closed May 4, 2022

620 Technology Dr, Ann Arbor, MI 48108 · Computer Terminal and Other Computer Peripheral Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10835(3)
Other-than-serious$0$0Mar 18, 2022Final

Inspection 308878313 OPENED JAN 31, 2008Closed

Complaint · Partial · Safety · 26 employees at the site · Closed Apr 21, 2008

4330 Varsity Dr, Ann Arbor, MI 48108 · Computer and Peripheral Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$375Mar 20, 2008Closed
Citation 2, item 1 Other-than-serious$0$0Mar 20, 2008Closed
Citation 2, item 2 Other-than-serious$0$0Mar 20, 2008Closed
Citation 2, item 3 Other-than-serious$0$0Mar 20, 2008Closed
Citation 2, item 4 Other-than-serious$0$0Mar 20, 2008Closed
Citation 2, item 5 Other-than-serious$0$0Mar 20, 2008Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Ann Arbor site logged 0 recordable injuries or illnesses among about 65 workers: 0.0 per 100 full-time workers, against a median of 0.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Dynics Inc
Ann Arbor · 2022
65 000.00.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 4080.1014

29 CFR 4081.213

29 CFR 4081.227

29 CFR 4081.3308

29 CFR 4082.2132

Other computer terminal and other computer peripheral equipment manufacturing employers in Michigan

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.