OSHA SearchOSHA records by employer

Dzars Electric, Inc.: OSHA inspections and violations

Brooklyn, New York · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
5citation items
$8,691current penalties
Mar 28, 2018last inspection

Since 2017, OSHA inspectors have visited Dzars Electric, Inc. in New York 2 times.

The most recent inspection opened on Mar 28, 2018 to follow up on an earlier case, in Brooklyn.

In all, OSHA issued 5 citation items: 5 serious.

The penalties, $8,691 in total, stand where OSHA first set them.

The rule cited most here is 1926.405 (job-site wiring), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Dzars Electric, Inc. averages $8,691 across 1 cited inspection.

Dzars Electric, Inc.: OSHA citation items per year, 2017 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

350employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Dzars Electric, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343053013 OPENED MAR 28, 2018Closed

Follow-up · Complete · Safety · 1 employee at the site · Closed Mar 28, 2018

410 Nostrand Ave., Brooklyn, NY 11216 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342361128 OPENED MAY 24, 2017Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jan 11, 2023

410 Nostrand Avenue, Brooklyn, NY 11216 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$2,897$2,897Aug 22, 2017Final
Citation 1, item 2a
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$2,897$2,897Aug 22, 2017Final
Citation 1, item 2b
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$0$0Aug 22, 2017Final
Citation 1, item 3a
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$2,897$2,897Aug 22, 2017Final
Citation 1, item 3b
29 CFR 1926.405(j)(1)(ii) · Job-site wiring
Serious$0$0Aug 22, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(e)

(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.

29 CFR 1926.405(a)(2)(ii)(f)

(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.

Other electrical contractors and other wiring installation contractors employers in New York