OSHA SearchOSHA records by employer

E & D Specialty Stands Inc: OSHA inspections and violations

Colonie, New York · All Other Miscellaneous Manufacturing · NAICS 339999

3inspections
17citation items
$10,620current penalties
Mar 23, 2026last inspection

OSHA has inspected E & D Specialty Stands Inc 3 times in New York since 1983.

The latest one began on Mar 23, 2026 on a referral, in Akron.

Those inspections ended with 17 citation items: 15 serious and 2 other-than-serious.

Penalties were first proposed at $15,960 and now stand at $10,620, 33% lower after settlements or reviews.

Mechanical power presses comes up most often in these citations: 5 items under 1910.217.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and E & D Specialty Stands Inc averages $1,845 (1 cited inspection).

E & D Specialty Stands Inc also files yearly injury logs with OSHA, summarized below.

E & D Specialty Stands Inc: OSHA citation items per year, 1983 to 2026
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch E & D Specialty Stands Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348840182 OPENED MAR 23, 2026Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jun 17, 2026

47 Bloomingdale Rd Akron High School, Akron, NY 14001 · All Other Miscellaneous Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.760(a)(1) · Fall protection
Serious$2,460$1,845Jun 3, 2026Final

Inspection 107347635 OPENED JAN 26, 1993Closed

Planned · Complete · Safety · 40 employees at the site · Closed May 6, 1993

2081 Franklin Street, North Collins, NY 14111 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(b)(4) · Exit route design
Serious$1,000$675Mar 17, 1993Closed
Citation 1, item 2
29 CFR 1910.37(f)(6) · Exit routes
Serious$1,000$675Mar 17, 1993Closed
Citation 1, item 3
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Serious$1,000$675Mar 17, 1993Closed
Citation 1, item 5
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,000$675Mar 17, 1993Closed
Citation 1, item 6
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$1,000$675Mar 17, 1993Closed
Citation 1, item 7
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$675Mar 17, 1993Closed
Citation 1, item 8
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,250$675Mar 17, 1993Closed
Citation 1, item 10
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$1,250$675Mar 17, 1993Closed
Citation 1, item 11
29 CFR 1910.217(c)(2)(ib) · Mechanical power presses
Serious$1,000$675Mar 17, 1993Closed
Citation 1, item 12
29 CFR 1910.217(d)(5) · Mechanical power presses
Serious$1,250$675Mar 17, 1993Closed
Citation 1, item 13
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$750$675Mar 17, 1993Closed
Citation 1, item 14
29 CFR 1910.304(e)(1)(i) · Grounding and circuit protection
Serious$750$675Mar 17, 1993Closed
Citation 1, item 15
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$338Mar 17, 1993Closed
Citation 1, item 16
29 CFR 1910.1200(h) · Hazard communication
Serious$750$338Mar 17, 1993Closed
Citation 2, item 1a
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Mar 17, 1993Closed
Citation 2, item 1b
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Other-than-serious$0$0Mar 17, 1993Closed

Inspection 10705697 OPENED JUL 21, 1983Closed

Complaint · Complete · Safety · 35 employees at the site · Closed Mar 22, 1984

Heritage Park Sports Facility, Colonie, NY 12205 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the North Collins site logged 0 recordable injuries or illnesses among about 45 workers: 0.0 per 100 full-time workers, against a median of 3.7 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
E & D Specialty Stands Inc
North Collins · 2025
45 000.03.7
E&D Specialty Stands, Inc.
North Collins · 2024
46 102.13.7

Included with any plan: 8 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(ii)

(ii) Containers when stored inside shall not be located near exits, stairways, or in areas normally used or intended for the safe exit of people.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1926.760 · Fall protection

Other all other miscellaneous manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.