OSHA SearchOSHA records by employer

E&L Diamond, Inc.: OSHA inspections and violations

Galax, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

8inspections
9citation items
$2,962current penalties
Apr 6, 2022last inspection

Since 2000, OSHA inspectors have visited E&L Diamond, Inc. in Virginia 8 times.

The most recent inspection opened on Apr 6, 2022 as a planned inspection, in Stuart.

In all, OSHA issued 9 citation items: 8 serious and 1 other-than-serious.

The proposed penalties came to $5,375; today they stand at $2,962, 45% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. E&L Diamond, Inc. averages $0 across 1 cited inspection.

E&L Diamond, Inc.: OSHA citation items per year, 2000 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch E&L Diamond, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345883730 OPENED APR 6, 2022Closed

Planned · Complete · Safety · 6 employees at the site · Closed May 16, 2022

967 Fairy Stone Lake Dr, Stuart, VA 24171 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.50(c) · Medical services and first aid
Other-than-serious$0$0Apr 11, 2022Final

Inspection 312306202 OPENED JUN 24, 2008Closed

Planned · Complete · Safety · 3 employees at the site · Closed Jun 24, 2008

289 Kohler Avenue, Austinville, VA 24312 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311887319 OPENED MAR 4, 2008Closed

Planned · Complete · Safety · 7 employees at the site · Closed Apr 1, 2008

289 Kohler Avenue, Austinville, VA 24312 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$525$315Mar 20, 2008Closed

Inspection 311801963 OPENED JAN 30, 2008Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 21, 2008

200 Maroon Tide Drive, Galax, VA 24333 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$875$525Mar 11, 2008Closed

Inspection 311583272 OPENED OCT 29, 2007Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 29, 2007

289 Kohler Avenue, Austinville, VA 24312 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311443055 OPENED SEP 10, 2007Closed

Planned · Complete · Safety · 6 employees at the site · Closed Sep 10, 2007

200 Maroon Tide Drive, Galax, VA 24333 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303905921 OPENED NOV 1, 2000Closed

Programmed other · Partial · Safety · 5 employees at the site · Closed Jan 4, 2001

15 Spradlin Farm Rd., Christiansburg, VA 24073 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$675$405Dec 7, 2000Closed
Citation 1, item 2
29 CFR 1926.50(c) · Medical services and first aid
Serious$675$405Dec 7, 2000Closed

Inspection 303249023 OPENED JUN 13, 2000Closed

Planned · Partial · Safety · 9 employees at the site · Closed Aug 4, 2000

100 Meadow Street, Galax, VA 24333 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$700$350Jul 27, 2000Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$525$262Jul 27, 2000Closed
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$700$350Jul 27, 2000Closed
Citation 1, item 4
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$700$350Jul 27, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.50 · Medical services and first aid

29 CFR 1926.501 · Fall protection in construction

Other electrical contractors and other wiring installation contractors employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.