OSHA SearchOSHA records by employer

E.J. Brown & Sons Contractors, Inc.: OSHA inspections and violations

Baldwinsville, New York · Framing Contractors · NAICS 238130

1inspections
6citation items
$3,000current penalties
May 18, 2015last inspection

E.J. Brown & Sons Contractors, Inc. has one OSHA inspection on record in New York.

OSHA opened it on May 18, 2015, in Baldwinsville.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $4,000 in penalties. After settlements and reviews the total is $3,000, down 25%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. E.J. Brown & Sons Contractors, Inc. averages $3,000 over 1 cited inspection in that time.

E.J. Brown & Sons Contractors, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

372employers cited

19 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch E.J. Brown & Sons Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340647809 OPENED MAY 18, 2015Closed

Unprogrammed other · Complete · Safety · 2 employees at the site · Closed Jun 19, 2015

The Intersection Of Spike Horn Path And Bucks Trail, Baldwinsville, NY 13027 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,200$900Jun 5, 2015Final
Citation 1, item 2a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$2,800$2,100Jun 5, 2015Final
Citation 1, item 2b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Jun 5, 2015Final
Citation 1, item 2c
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$0$0Jun 5, 2015Final
Citation 1, item 2d
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Jun 5, 2015Final
Citation 1, item 2e
29 CFR 1926.452(w)(6)(v) · Rules for each type of scaffold
Serious$0$0Jun 5, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.452 · Rules for each type of scaffold

Other framing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.