OSHA SearchOSHA records by employer

Eagle Concrete Inc: OSHA inspections and violations

Jersey City, New Jersey · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
3citation items
$12,288current penalties
Jul 28, 2021last inspection

OSHA has inspected Eagle Concrete Inc once in New Jersey.

The inspection began on Jul 28, 2021 on a referral, in Jersey City.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $12,288 and still stand at $12,288.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Eagle Concrete Inc averages $12,288 (1 cited inspection).

Eagle Concrete Inc: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

272employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Eagle Concrete Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345446751 OPENED JUL 28, 2021Closed

Referral · Partial · Safety · 5 employees at the site · Closed Mar 2, 2026

400 Claremont Ave, Jersey City, NJ 07304 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$4,096$4,096Nov 18, 2021Final
Citation 1, item 2
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$4,096$4,096Nov 18, 2021Final
Citation 1, item 3
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,096$4,096Nov 18, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

Other poured concrete foundation and structure contractors employers in New Jersey