OSHA SearchOSHA records by employer

Eagle Electric Inc: OSHA inspections and violations

Jacksonville Beach, Florida · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

3inspections
7citation items
$3,145current penalties
Jun 9, 2026last inspection

OSHA has inspected Eagle Electric Inc 3 times in Florida since 2008.

The latest one began on Jun 9, 2026 after a complaint, in Jacksonville.

Those inspections ended with 7 citation items: 4 serious and 3 other-than-serious.

Penalties were first proposed at $5,033 and now stand at $3,145, 38% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 4 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Eagle Electric Inc averages $596 (1 cited inspection).

Eagle Electric Inc: OSHA citation items per year, 2008 to 2026
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

338employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Eagle Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348985490 OPENED JUN 9, 2026Closed

Complaint · Partial · Safety · 35 employees at the site · Closed Aug 18, 2026

New Construction Project (gate Gas Station) Normandy & Pow Memorial Highway, Jacksonville, FL 32210 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.41(a)(1)(i) · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA
Other-than-serious$993$596Jun 12, 2026Final

Inspection 315479014 OPENED AUG 10, 2011Closed

Unprogrammed related · Partial · Safety · 2 employees at the site · Closed Sep 21, 2011

620 Atlantic Blvd, Neptune Beach, FL 32266 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(a)(2)(iib) · Job-site wiring
Serious$2,640$1,848Aug 25, 2011Closed
Citation 1, item 1b
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$0$0Aug 25, 2011Closed
Citation 1, item 1c
29 CFR 1926.405(a)(2)(iie) · Job-site wiring
Serious$0$0Aug 25, 2011Closed
Citation 1, item 1d
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$0$0Aug 25, 2011Closed

Inspection 311817654 OPENED SEP 18, 2008Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 7, 2008

319 S Third Street, Jacksonville Beach, FL 32250 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$700$351Sep 23, 2008Closed
Citation 1, item 2
29 CFR 1926.1060(a) · Ladder and stairway training
Other-than-serious$700$350Sep 23, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.41 · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA

29 CFR 1904.41(a)(1)(i)

(a) Basic requirements—(1) Annual electronic submission of information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses. (i) If your establishment had 20-249 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.405 · Job-site wiring

Other electrical contractors and other wiring installation contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.