3inspections
6citation items
$3,600current penalties
Oct 14, 2026last inspection

Eagle Pallets Inc. has 3 OSHA inspections on record in Illinois, the first in 2024.

OSHA's last visit started on Oct 14, 2026 after a fatality or catastrophe, in Joliet, and the case has not closed yet.

Across those inspections OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

OSHA proposed $6,914 in penalties. After settlements and reviews the total is $3,600, down 48%.

Most often, OSHA cited 1910.219, belts, pulleys and power-transmission parts (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Eagle Pallets Inc. averages $1,800 over 2 cited inspections in that time.

Eagle Pallets Inc.: OSHA citation items per year, 2024 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Eagle Pallets Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 349219899 OPENED OCT 14, 2026Open

Fatality or catastrophe · Partial · Safety · 11 employees at the site · Open

220 Colburn Ave., Joliet, IL 60433 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 347898140 OPENED NOV 22, 2024Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 14, 2025

220 Colburn Avenue, Joliet, IL 60433 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$3,457$1,800Dec 20, 2024Final
Citation 1, item 1b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 20, 2024Final
Citation 1, item 1c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Dec 20, 2024Final
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 20, 2024Final

Inspection 347866980 OPENED NOV 7, 2024Closed

Planned · Partial · Health · 4 employees at the site · Closed Jan 14, 2025

220 Colburn Avenue, Joliet, IL 60433 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$3,457$1,800Dec 12, 2024Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 12, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1910.219(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise