OSHA SearchOSHA records by employer

Earl's Plumbing & Heating, LLC: OSHA inspections and violations

Metairie, Louisiana · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

1inspections
4citation items
$24,844current penalties
Aug 16, 2017last inspection

OSHA has inspected Earl's Plumbing & Heating, LLC once in Louisiana.

The inspection began on Aug 16, 2017 as a planned inspection, in Metairie.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $35,492 and now stand at $24,844, 30% lower after settlements or reviews.

Excavations comes up most often in these citations: 3 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Earl's Plumbing & Heating, LLC averages $24,844 (1 cited inspection).

Earl's Plumbing & Heating, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

18employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Earl's Plumbing & Heating, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342667227 OPENED AUG 16, 2017Closed

Planned · Partial · Safety · 40 employees at the site · Closed Dec 21, 2018

1409 Upland St., Metairie, LA 70003 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$8,873$6,211Dec 7, 2017Final
Citation 1, item 2
29 CFR 1926.651(h)(1) · Excavations
Serious$8,873$6,211Dec 7, 2017Final
Citation 1, item 3
29 CFR 1926.651(i)(1) · Excavations
Serious$8,873$6,211Dec 7, 2017Final
Citation 1, item 4
29 CFR 1926.651(k)(1) · Excavations
Serious$8,873$6,211Dec 7, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(h)(1)

(h) Protection from hazards associated with water accumulation. (1) Employees shall not work in excavations in which there is accumulated water, or in excavations in which water is accumulating, unless adequate precautions have been taken to protect employees against the hazards posed by water accumulation. The precautions necessary to protect employees adequately vary with each situation, but could include special support or shield systems to protect from cave-ins, water removal to control the level of accumulating water, or use of a safety harness and lifeline.

29 CFR 1926.651(i)(1)

(i) Stability of adjacent structures. (1) Where the stability of adjoining buildings, walls, or other structures is endangered by excavation operations, support systems such as shoring, bracing, or underpinning shall be provided to ensure the stability of such structures for the protection of employees.

Other plumbing, heating, and air-conditioning contractors employers in Louisiana

Alert subscribers get notified of each newly cited employer in Louisiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.