OSHA SearchOSHA records by employer

Easom Automation Systems Inc: OSHA inspections and violations

Madison Heights, Michigan · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · NAICS 333514

3inspections
24citation items
$5,700current penalties
Aug 7, 2018last inspection

Easom Automation Systems Inc has 3 OSHA inspections on record in Michigan, the first in 2003.

OSHA's last visit started on Aug 7, 2018 as a planned inspection, in Madison Heights.

Across those inspections OSHA issued 24 citation items: 16 serious and 8 other-than-serious.

OSHA proposed $10,800 in penalties. After settlements and reviews the total is $5,700, down 47%.

Most often, OSHA cited 1910.134, respiratory protection (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Easom Automation Systems Inc averages $2,550 over 2 cited inspections in that time.

Easom Automation Systems Inc also files yearly injury logs with OSHA, summarized below.

Easom Automation Systems Inc: OSHA citation items per year, 2003 to 2018
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

647employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Easom Automation Systems Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343364915 OPENED AUG 7, 2018Closed

Planned · Complete · Safety · 58 employees at the site · Closed Oct 2, 2018

32471 Industrial Dr, Madison Heights, MI 48071 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10125
Other-than-serious$0$0Sep 7, 2018Final
Citation 1, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 7, 2018Final

Inspection 340076728 OPENED NOV 12, 2015Closed

Planned · Complete · Safety · 120 employees at the site · Closed Dec 30, 2015

32471 Industrial Dr, Madison Heights, MI 48071 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(7)
Serious$900$450Dec 8, 2015Final
Citation 1, item 2
29 CFR 408.10034(9)
Serious$900$450Dec 8, 2015Final
Citation 1, item 3
29 CFR 408.10213(2)
Serious$1,200$600Dec 8, 2015Final
Citation 1, item 4
29 CFR 408.10220(1)
Serious$1,200$600Dec 8, 2015Final
Citation 1, item 5
29 CFR 408.11115(4)
Serious$1,200$600Dec 8, 2015Final
Citation 1, item 6
29 CFR 408.11211(1)(D)
Serious$900$450Dec 8, 2015Final
Citation 1, item 7
29 CFR 408.12635(1)(A)
Serious$900$450Dec 8, 2015Final
Citation 1, item 8a
29 CFR 408.12730(1)
Serious$1,200$600Dec 8, 2015Final
Citation 1, item 8b
29 CFR 408.12730(6)
Serious$0$0Dec 8, 2015Final
Citation 1, item 9
29 CFR 408.13312(1)
Serious$900$450Dec 8, 2015Final
Citation 1, item 10
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$900$450Dec 8, 2015Final
Citation 2, item 1
29 CFR 408.10036(1)
Other-than-serious$0$0Dec 8, 2015Final
Citation 2, item 2
29 CFR 408.10215(2)
Other-than-serious$0$0Dec 8, 2015Final
Citation 2, item 3
29 CFR 408.11854(1)
Other-than-serious$0$0Dec 8, 2015Final
Citation 2, item 4
29 CFR 408.11871(2)
Other-than-serious$0$0Dec 8, 2015Final
Citation 2, item 5
29 CFR 408.12015(2)
Other-than-serious$0$0Dec 8, 2015Final
Citation 2, item 6
29 CFR 408.12154(1)
Other-than-serious$0$0Dec 8, 2015Final

Inspection 125137653 OPENED MAR 25, 2003Closed

Referral · Partial · Health · 40 employees at the site · Closed Sep 5, 2003

2761 Stair Ave, Detroit, MI 48209 · Industrial Mold Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$600$600May 21, 2003Closed
Citation 1, item 1b
29 CFR 1910.134(i)(1)(ii) · Respiratory protection
Serious$0$0May 21, 2003Closed
Citation 1, item 1c
29 CFR 1910.134(i)(5)(iii) · Respiratory protection
Serious$0$0May 21, 2003Closed
Citation 1, item 1d
29 CFR 1910.134(i)(5)(iv) · Respiratory protection
Serious$0$0May 21, 2003Closed
Citation 1, item 1e
29 CFR 1910.134(i)(8) · Respiratory protection
Serious$0$0May 21, 2003Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2019, the Madison Heights site logged 0 recordable injuries or illnesses among about 61 workers: 0.0 per 100 full-time workers, against a median of 1.9 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Easom Automation Systems, Inc
Madison Heights · 2019
61 000.01.9

Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

Other special die and tool, die set, jig, and fixture manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.