Inspection 343192191 OPENED MAY 31, 2018Closed
80 Columbia Turnpike, Rensselaer, NY 12144 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rensselaer, New York · Sewage Treatment Facilities · NAICS 221320
East Greenbush TN WWTP has 6 OSHA inspections on record in New York, the first in 1999.
OSHA's last visit started on May 31, 2018 to follow up on an earlier case, in Rensselaer.
Across those inspections OSHA issued 19 citation items: 13 serious and 6 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1910.305, electrical wiring methods (4 items).
For context, across all utility employers the median penalty per cited inspection since 2015 is $0. East Greenbush TN WWTP averages $0 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
372employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch East Greenbush TN WWTP and get notified the morning OSHA posts a new citation for it.
Watch this company80 Columbia Turnpike, Rensselaer, NY 12144 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
80 Columbia Turnpike, Rensselaer, NY 12144 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $0 | $0 | Apr 18, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 18, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.303(c)(3)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 18, 2018 | Final |
| Citation 1, item 4 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 18, 2018 | Final |
| Citation 1, item 5 29 CFR 1910.304(b)(3)(i) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 18, 2018 | Final |
| Citation 1, item 6 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Serious | $0 | $0 | Apr 18, 2018 | Final |
| Citation 1, item 7 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Apr 18, 2018 | Final |
80 Columbia Turnpike, Rensselaer, NY 12144 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
80 Columbia Turnpike, Rensselaer, NY 12144 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.253(a)(1) · Gas welding and cutting |
Serious | $0 | $0 | Jul 28, 2006 | Closed |
| Citation 1, item 2 29 CFR 1910.266(d)(1)(iv) · Logging operations |
Serious | $0 | $0 | Jul 28, 2006 | Closed |
| Citation 1, item 3 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Jul 28, 2006 | Closed |
| Citation 2, item 1 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 28, 2006 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Jul 28, 2006 | Closed |
80 Columbia Turnpike, Rensselaer, NY 12144 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
80 Columbia Turnpike, Rensselaer, NY 12144 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(c) · General requirements |
Serious | $0 | $0 | Aug 26, 1999 | Closed |
| Citation 1, item 2 29 CFR 1910.147(c)(5)(ii) · Lockout/tagout |
Serious | $0 | $0 | Aug 26, 1999 | Closed |
| Citation 1, item 3 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $0 | $0 | Aug 26, 1999 | Closed |
| Citation 2, item 1 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Closed |
| Citation 2, item 2 29 CFR 1910.23(e)(5)(iv) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Closed |
| Citation 2, item 3 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Closed |
| Citation 2, item 4 29 CFR 1910.305(a)(1)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Aug 26, 1999 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(f)(5)(i)
(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).
29 CFR 1910.1200(h)
(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.
29 CFR 1910.147(c)(5)(ii)
(ii) Lockout devices and tagout devices shall be singularly identified; shall be the only devices(s) used for controlling energy; shall not be used for other purposes; and shall meet the following requirements:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.