OSHA SearchOSHA records by employer

Eastex Utility Construction LLC: OSHA inspections and violations

Spring, Texas · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$21,064current penalties
Feb 24, 2021last inspection

OSHA inspectors have visited Eastex Utility Construction LLC in Texas one time.

It opened on Feb 24, 2021 as a planned inspection, in Spring.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $21,064 in total, stand where OSHA first set them.

The rule cited most here is 1926.651 (excavations), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Eastex Utility Construction LLC averages $21,064 across 1 cited inspection.

Eastex Utility Construction LLC: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Eastex Utility Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345167449 OPENED FEB 24, 2021Closed

Planned · Partial · Safety · 11 employees at the site · Closed Jun 21, 2021

Near 6400 Spring Stubner Road, Spring, TX 77379 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$4,681$4,681May 21, 2021Final
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$5,461$5,461May 21, 2021Final
Citation 1, item 3
29 CFR 1926.651(k)(2) · Excavations
Serious$5,461$5,461May 21, 2021Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$5,461$5,461May 21, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(2)

(2) Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.