OSHA SearchOSHA records by employer

Eastside Electric Motors LLC: OSHA inspections and violations

Boardman, Oregon · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
3citation items
$7,000current penalties
Oct 29, 2015last inspection

OSHA inspectors have visited Eastside Electric Motors LLC in Oregon one time.

It opened on Oct 29, 2015 after an accident, in Boardman.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $7,000 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Eastside Electric Motors LLC averages $7,000 across 1 cited inspection.

Eastside Electric Motors LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Eastside Electric Motors LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341045680 OPENED OCT 29, 2015Closed

Accident · Partial · Safety · 1 employee at the site · Closed Aug 22, 2016

Rdo Farms 75906 Three Mile Rd, Boardman, OR 97818 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(b)(2)(ii)(b) · Working near live electrical parts
Serious$2,800$2,800Feb 18, 2016Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,800$2,800Feb 18, 2016Final
Citation 1, item 3
29 CFR OAR 437-002-0134(1)(A)
Serious$1,400$1,400Feb 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(b)(2)(ii)(b)

(B) The circuits and equipment to be worked on shall be disconnected from all electric energy sources. Control circuit devices, such as push buttons, selector switches, and interlocks, may not be used as the sole means for deenergizing circuits or equipment. Interlocks for electric equipment may not be used as a substitute for lockout and tagging procedures.

Other electrical contractors and other wiring installation contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.