OSHA SearchOSHA records by employer

Eau Claire Roofing Company, Inc.: OSHA inspections and violations

Eau Claire, Wisconsin · Roofing Contractors · NAICS 238160

7inspections
21citation items
$19,067current penalties
Apr 25, 2023last inspection

Since 2006, OSHA inspectors have visited Eau Claire Roofing Company, Inc. in Wisconsin 7 times.

The most recent inspection opened on Apr 25, 2023 as a planned inspection, in Menomonie.

In all, OSHA issued 21 citation items: 19 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $27,086; today they stand at $19,067, 30% less.

The rule cited most here is 1926.501 (fall protection in construction), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Eau Claire Roofing Company, Inc. averages $3,886 across 2 cited inspections.

Eau Claire Roofing Company, Inc.: OSHA citation items per year, 2006 to 2023
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Eau Claire Roofing Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346657208 OPENED APR 25, 2023Closed

Planned · Partial · Safety · 2 employees at the site · Closed May 19, 2023

2407 Stout Road, Menomonie, WI 54751 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$6,875$4,812May 4, 2023Final

Inspection 345940548 OPENED MAY 5, 2022Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Oct 26, 2022

2215 Folsom Street, Eau Claire, WI 54703 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(d)(8) · Fall protection systems
Serious$4,931$2,959Sep 30, 2022Final
Citation 1, item 1c
29 CFR 1926.503(a)(2)(ii) · Fall protection training in construction
Serious$0$0Sep 30, 2022Final
Citation 2, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0Sep 30, 2022Final

Inspection 340016138 OPENED OCT 17, 2014Closed

Planned · Partial · Safety · 9 employees at the site · Closed Feb 19, 2016

3105 S. Lexington Blvd., Eau Claire, WI 54701 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$3,200$2,240Oct 31, 2014Final

Inspection 339464166 OPENED NOV 1, 2013Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Nov 27, 2013

2851 Hedrickson Drive, Eau Claire, WI 54701 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,000$1,400Nov 8, 2013Final

Inspection 331096842 OPENED DEC 2, 2011Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Dec 20, 2011

3345/3347 Runway Ave, Eau Claire, WI 54703 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,550$1,785Dec 5, 2011Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,530$1,071Dec 5, 2011Final

Inspection 313176158 OPENED NOV 6, 2009Closed

Planned · Partial · Safety · 5 employees at the site · Closed May 13, 2010

2653 113th Street, Chippewa Falls, WI 54729 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$750$750Nov 23, 2009Closed
Citation 1, item 1b
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$0$0Nov 23, 2009Closed
Citation 1, item 1c
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$0$0Nov 23, 2009Closed
Citation 1, item 2a
29 CFR 1926.451(e)(5)(i) · Scaffolds, general requirements
Serious$750$750Nov 23, 2009Closed
Citation 1, item 2b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Nov 23, 2009Closed
Citation 1, item 3
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$750$750Nov 23, 2009Closed
Citation 1, item 4a
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$750$750Nov 23, 2009Closed
Citation 1, item 4b
29 CFR 1926.501(c) · Fall protection in construction
Serious$0$0Nov 23, 2009Closed

Inspection 307041624 OPENED OCT 10, 2006Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Feb 13, 2007

Super Value 142 E Hudson St., Mondovi, WI 54755 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$750$450Oct 15, 2006Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Oct 15, 2006Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$900Oct 15, 2006Closed
Citation 1, item 2b
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Oct 15, 2006Closed
Citation 1, item 3
29 CFR 1926.1053(b)(22) · Ladders in construction
Serious$750$450Oct 15, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(22)

(22) An employee shall not carry any object or load that could cause the employee to lose balance and fall.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.