Inspection 342319738 OPENED MAY 11, 2017Closed
130 Kirk Avenue, Pittsburgh, PA 15227 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pittsburgh, Pennsylvania · Siding Contractors · NAICS 238170
OSHA has inspected Eber David Vasquez 2 times in Pennsylvania since 2016.
The latest one began on May 11, 2017 to follow up on an earlier case, in Pittsburgh.
Those inspections ended with 4 citation items: 4 serious.
Penalties were first proposed at $7,606 and still stand at $7,606.
Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Eber David Vasquez averages $7,606 (1 cited inspection).
Pennsylvania · latest 90 days of OSHA records
295employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Eber David Vasquez and get notified the morning OSHA posts a new citation for it.
Watch this company130 Kirk Avenue, Pittsburgh, PA 15227 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
130 Kirk Avenue, Pittsburgh, PA 15227 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements |
Serious | $3,803 | $3,803 | Feb 9, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements |
Serious | $0 | $0 | Feb 9, 2017 | Final |
| Citation 1, item 1c 29 CFR 1926.452(j)(2) · Rules for each type of scaffold |
Serious | $0 | $0 | Feb 9, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $3,803 | $3,803 | Feb 9, 2017 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(5)(ii)
(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.
29 CFR 1926.451(g)(1)(vii)
(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.
29 CFR 1926.452(j)(2)
(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.