Inspection 340667526 OPENED MAY 20, 2015Closed
255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Ebsco Industries, Inc. has 4 OSHA inspections on record in Nevada, the first in 2014.
OSHA's last visit started on May 20, 2015 on a referral, in Fernley.
Across those inspections OSHA issued 5 citation items: 2 serious, 1 repeat and 2 other-than-serious.
OSHA proposed $4,400 in penalties. After settlements and reviews the total is $3,230, down 27%.
Most often, OSHA cited 1910.219, belts, pulleys and power-transmission parts (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Ebsco Industries, Inc. averages $2,730 over 1 cited inspection in that time.
Nevada · latest 90 days of OSHA records
114employers cited
Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Nevada
Checking a subcontractor, a client or your own company? Watch Ebsco Industries, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Repeat | $2,800 | $1,960 | Jul 16, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.212(a)(3)(iv)(b) · Machine guarding |
Serious | $1,100 | $770 | Jul 16, 2015 | Final |
255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
255 Logan Road, Fernley, NV 89408 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.243(c)(3) · Guarding of portable powered tools |
Serious | $500 | $500 | Nov 17, 2014 | Final |
| Citation 2, item 1 29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes |
Other-than-serious | $0 | $0 | Nov 17, 2014 | Final |
| Citation 2, item 2 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Other-than-serious | $0 | $0 | Nov 17, 2014 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.179(g)(1)(v)
(v) Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions.
29 CFR 1910.212(a)(3)(iv)(b)
(iv) The following are some of the machines which usually require point of operation guarding:
29 CFR 1910.219(f)(3)
(3) Sprockets and chains. All sprocket wheels and chains shall be enclosed unless they are more than seven (7) feet above the floor or platform. Where the drive extends over other machine or working areas, protection against falling shall be provided. This subparagraph does not apply to manually operated sprockets.
Alert subscribers get notified of each newly cited employer in Nevada the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.