2inspections
17citation items
$26,000current penalties
Feb 26, 2025last inspection

Since 2025, OSHA inspectors have visited Econ Welding & Fabrication, LLC in Illinois 2 times.

The most recent inspection opened on Feb 26, 2025 after a complaint, in Wauconda.

In all, OSHA issued 17 citation items: 16 serious and 1 other-than-serious.

The proposed penalties came to $44,925; today they stand at $26,000, 42% less.

The rule cited most here is 1910.134 (respiratory protection), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Econ Welding & Fabrication, LLC averages $13,000 across 2 cited inspections.

Econ Welding & Fabrication, LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Econ Welding & Fabrication, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348067208 OPENED FEB 26, 2025Closed

Complaint · Partial · Health · 12 employees at the site · Closed Nov 3, 2026

1001 N Rand Road Suite 107, Wauconda, IL 60084 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(e) · Personal protective equipment, general requirements
Other-than-serious$3,215$1,800Jul 11, 2025Final
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$4,729$3,100Jul 11, 2025Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Jul 11, 2025Final
Citation 1, item 2c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Jul 11, 2025Final
Citation 1, item 2d
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Jul 11, 2025Final
Citation 1, item 2e
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$4,729$0Jul 11, 2025Final
Citation 1, item 4
29 CFR 1910.242(b) · Hand and power tools
Serious$4,729$3,200Jul 11, 2025Final
Citation 1, item 5
29 CFR 1910.252(b)(2)(iii) · Welding fire safety
Serious$4,729$3,200Jul 11, 2025Final
Citation 1, item 6
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$4,729$3,200Jul 11, 2025Final
Citation 1, item 7a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$4,729$3,500Jul 11, 2025Final
Citation 1, item 7b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jul 11, 2025Final
Citation 1, item 7c
29 CFR 1910.1026(l)(1)(i) · Hexavalent chromium
Serious$0$0Jul 11, 2025Final
Citation 1, item 7d
29 CFR 1910.1026(l)(2) · Hexavalent chromium
Serious$0$0Jul 11, 2025Final

Inspection 348067679 OPENED FEB 26, 2025Closed

Complaint · Partial · Safety · 12 employees at the site · Closed Sep 29, 2025

1001 N Rand Road Suite 107, Wauconda, IL 60084 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,729$3,000Jul 11, 2025Final
Citation 1, item 2
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$3,783$2,500Jul 11, 2025Final
Citation 1, item 3a
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$2,412$2,500Jul 11, 2025Final
Citation 1, item 3b
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$2,412$0Jul 11, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1026(l)(1)(i)

(l) Communication of chromium (VI) hazards to employees—(1) Hazard communication—general—(i) Chemical manufacturers, importers, distributors and employers shall comply with all requirements of the Hazard Communication Standard (HCS) (§ 1910.1200) for chromium (VI).

29 CFR 1910.1026(l)(2)

(l) Communication of chromium (VI) hazards to employees—(1) Hazard communication—general—(i) Chemical manufacturers, importers, distributors and employers shall comply with all requirements of the Hazard Communication Standard (HCS) (§ 1910.1200) for chromium (VI).

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other plate work manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.