OSHA SearchOSHA records by employer

ED Alphonse Contracting, Inc.: OSHA inspections and violations

Jacksonville, Florida · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
6citation items
$5,292current penalties
May 29, 2015last inspection

OSHA has inspected ED Alphonse Contracting, Inc. once in Florida.

The inspection began on May 29, 2015 as a planned inspection, in Jacksonville.

That inspection ended with 6 citation items: 6 serious.

Penalties were first proposed at $8,820 and now stand at $5,292, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and ED Alphonse Contracting, Inc. averages $5,292 (1 cited inspection).

ED Alphonse Contracting, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch ED Alphonse Contracting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340666841 OPENED MAY 29, 2015Closed

Planned · Complete · Safety · 7 employees at the site · Closed Sep 29, 2016

9401 Staples Mill Drive, Jacksonville, FL 32244 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,410$2,646Aug 17, 2015Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Aug 17, 2015Final
Citation 1, item 1c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Aug 17, 2015Final
Citation 1, item 1d
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 17, 2015Final
Citation 1, item 2a Serious$4,410$2,646Aug 17, 2015Final
Citation 1, item 2b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Aug 17, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other poured concrete foundation and structure contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.