OSHA SearchOSHA records by employer

ED Pierce Masonry, Inc.: OSHA inspections and violations

Coeur D Alene, Idaho · Masonry Contractors · NAICS 238140

1inspections
3citation items
$2,200current penalties
May 30, 2018last inspection

OSHA inspectors have visited ED Pierce Masonry, Inc. in Idaho one time.

It opened on May 30, 2018 after a complaint, in Coeur D Alene.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $3,880; today they stand at $2,200, 43% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. ED Pierce Masonry, Inc. averages $2,200 across 1 cited inspection.

ED Pierce Masonry, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Idaho · latest 90 days of OSHA records

62employers cited

Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Idaho

Checking a subcontractor, a client or your own company? Watch ED Pierce Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343201224 OPENED MAY 30, 2018Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Sep 27, 2018

1812 N. Lakewood Dr., Coeur D Alene, ID 83814 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,880$2,200Jun 15, 2018Final
Citation 1, item 1b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Jun 15, 2018Final
Citation 1, item 1c
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$0$0Jun 15, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.451(g)(4)(xv)

(xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The end points at each upright shall be no more than 48 inches (1.3 m) apart.

29 CFR 1926.451(h)(2)(ii)

(ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3/4 × 1 1/2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards;

Other masonry contractors employers in Idaho

Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.