OSHA SearchOSHA records by employer

Eddie Gullett Roofing LLC: OSHA inspections and violations

Naples, Florida · Roofing Contractors · NAICS 238160

1inspections
1citation items
$2,173current penalties
Nov 9, 2017last inspection

Eddie Gullett Roofing LLC has one OSHA inspection on record in Florida.

OSHA opened it on Nov 9, 2017 after a complaint, in Naples.

From that inspection OSHA issued 1 citation item: 1 serious.

OSHA proposed $2,173 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Eddie Gullett Roofing LLC averages $2,173 over 1 cited inspection in that time.

Eddie Gullett Roofing LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Eddie Gullett Roofing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342765294 OPENED NOV 9, 2017Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Apr 11, 2023

9156 Pinnacle Court, Naples, FL 34113 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$2,173$2,173Nov 27, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.