OSHA SearchOSHA records by employer

Edgar Sarmiento: OSHA inspections and violations

Corpus Christi, Texas · Framing Contractors · NAICS 238130

1inspections
2citation items
$2,000current penalties
Mar 13, 2019last inspection

OSHA has inspected Edgar Sarmiento once in Texas.

The inspection began on Mar 13, 2019 as a planned inspection, in Corpus Christi.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $3,978 and now stand at $2,000, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Edgar Sarmiento averages $2,000 (1 cited inspection).

Edgar Sarmiento: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Edgar Sarmiento and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343853479 OPENED MAR 13, 2019Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jul 14, 2022

239 Ohio Ave, Corpus Christi, TX 78404 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$3,978$2,000Apr 11, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Apr 11, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

Other framing contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.