OSHA SearchOSHA records by employer

Edj Development LLC: OSHA inspections and violations

Flemington, New Jersey · Siding Contractors · NAICS 238170

1inspections
3citation items
$6,126current penalties
May 30, 2018last inspection

OSHA has inspected Edj Development LLC once in New Jersey.

The inspection began on May 30, 2018 after a complaint, in Flemington.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $9,424 and now stand at $6,126, 35% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Edj Development LLC averages $6,126 (1 cited inspection).

Edj Development LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Edj Development LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343190393 OPENED MAY 30, 2018Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Nov 13, 2019

61 Bonnell St, Flemington, NJ 08822 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,772$1,802Jun 14, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,880$2,522Jun 14, 2018Final
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$2,772$1,802Jun 14, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

Other siding contractors employers in New Jersey

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.