OSHA SearchOSHA records by employer

EE Cruz & Company Inc.: OSHA inspections and violations

New York, New York · Other Heavy and Civil Engineering Construction · NAICS 237990

2inspections
5citation items
$34,284current penalties
Jan 12, 2018last inspection

OSHA has inspected EE Cruz & Company Inc. 2 times in New York since 2013.

The latest one began on Jan 12, 2018 on a referral, in Pelham.

Those inspections ended with 5 citation items: 1 serious and 4 other-than-serious.

Penalties were first proposed at $41,502 and now stand at $34,284, 17% lower after settlements or reviews.

Power line safety (up to 350 kV)—equipment operations comes up most often in these citations: 3 items under 1926.1408.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and EE Cruz & Company Inc. averages $32,934 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

EE Cruz & Company Inc.: OSHA citation items per year, 2013 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

366employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch EE Cruz & Company Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342877958 OPENED JAN 12, 2018Closed

Referral · Partial · Safety · 6 employees at the site · Closed Aug 6, 2018

5 Secor Lane, Pelham, NY 10803 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Incident on Jan 11, 2018: Employee is shocked while grasping jersey barrier clamp

At 2:00 p.m. on January 11, 2018, Employee #1 and a coworker, employed by a construction company, were working on a highway maintenance/repair project. The coworker operating a 12-foot high rough terrain crane to lift a jersey barrier onto a flatbed truck, while Employee #1 was grasping the jersey barrier clamp, which was connected to the crane boom's whip line, and guiding the jersey barrier. The distance from the ground up to the lowest electrical conductor was approximately 20 feet, leaving a clearance of 8 feet between the crane and the conductor. As Employee #1 held onto the metal clamp, he sustained an electrical shock. Emergency services were called and, upon arrival, Employee #1 was transported to the hospital where he was admitted and received treatment for electrical shock.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1408(a)(2)(iii)(b) · Power line safety (up to 350 kV)—equipment operations
Serious$12,934$12,934Jun 15, 2018Final
Citation 1, item 2
29 CFR 1926.1408(b)(4)(ii)(a) · Power line safety (up to 350 kV)—equipment operations
Other-than-serious$12,934$10,000Jun 15, 2018Final
Citation 1, item 3
29 CFR 1926.1408(b)(4)(ii)(b) · Power line safety (up to 350 kV)—equipment operations
Other-than-serious$12,934$10,000Jun 15, 2018Final

Inspection 338925803 OPENED FEB 25, 2013Closed

Unprogrammed related · Partial · Health · 250 employees at the site · Closed Aug 1, 2013

3205 Broadway, New York, NY 10027 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.65(c)(8) · Hazardous waste operations and emergency response
Other-than-serious$2,700$1,350Jul 1, 2013Final
Citation 2, item 1
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Other-than-serious$0$0Jul 1, 2013Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 11, 2018, Pelham: Hospitalization · electrocutions, electric shocks · body systems

An employee received an electric shock while working near a crane and powerlines.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(g)(1)(i)(a)

(A) Facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function; or

29 CFR 1926.1408 · Power line safety (up to 350 kV)—equipment operations

29 CFR 1926.1408(a)(2)(iii)(b)

(B) Determine if any part of the equipment, load line or load (including rigging and lifting accessories), while operating up to the equipment's maximum working radius in the work zone, could get closer than the minimum approach distance of the power line permitted under Table A (see § 1926.1408). If so, then the employer must follow the requirements in paragraph (b) of this section to ensure that no part of the equipment, load line, or load (including rigging and lifting accessories), gets closer to the line than the minimum approach distance.

29 CFR 1926.1408(b)(4)(ii)(a)

(A) Be equipped with a visual aid to assist in identifying the minimum clearance distance. Examples of a visual aid include, but are not limited to: A clearly visible line painted on the ground; a clearly visible line of stanchions; a set of clearly visible line-of-sight landmarks (such as a fence post behind the dedicated spotter and a building corner ahead of the dedicated spotter).

29 CFR 1926.65 · Hazardous waste operations and emergency response

Other other heavy and civil engineering construction employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.