OSHA SearchOSHA records by employer

Efh Co: OSHA inspections and violations

Burnsville, Minnesota · Commercial and Institutional Building Construction · NAICS 236220

19inspections
8citation items
$3,135current penalties
May 6, 2021last inspection

OSHA has inspected Efh Co 19 times in Minnesota since 1986.

The latest one began on May 6, 2021 as a planned inspection, in Dundas.

Those inspections ended with 8 citation items: 7 serious and 1 other-than-serious.

Penalties were first proposed at $4,950 and now stand at $3,135, 37% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Efh Co averages $2,250 (1 cited inspection).

Efh Co: OSHA citation items per year, 1986 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Efh Co again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345324503 OPENED MAY 6, 2021Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 9, 2021

404 Schilling Drive, Dundas, MN 55019 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$375$225Jun 15, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,050$630Jun 15, 2021Final
Citation 1, item 3
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$1,050$630Jun 15, 2021Final
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$1,050$630Jun 15, 2021Final
Citation 1, item 5
29 CFR 1926.451(h)(2) · Scaffolds, general requirements
Serious$225$135Jun 15, 2021Final

Inspection 342248291 OPENED APR 12, 2017Closed

Planned · Complete · Safety · 1 employee at the site · Closed Apr 27, 2017

1770 Old Hudson Road, Saint Paul, MN 55106 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341877926 OPENED OCT 31, 2016Closed

Planned · Complete · Safety · 1 employee at the site · Closed Nov 2, 2016

441 Highway 96 West, Saint Paul, MN 55126 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314667361 OPENED JUL 12, 2010Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 20, 2010

5710 Xerxes Avenue North, Brooklyn Center, MN 55430 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314066028 OPENED DEC 31, 2009Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jan 13, 2010

6880 Boudin Street, Prior Lake, MN 55372 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313561763 OPENED JUL 2, 2009Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 21, 2009

1654 Diffley Road, Eagan, MN 55125 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312442064 OPENED JUL 25, 2008Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 31, 2008

11129 162nd Street West, Lakeville, MN 55044 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311362198 OPENED AUG 22, 2007Closed

Planned · Complete · Safety · 1 employee at the site · Closed Aug 23, 2007

14771 Energy Way, Apple Valley, MN 55124 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

11 older inspections

Inspection 311276042 OPENED JUL 30, 2007Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 4, 2007

12425 River Ridge Blvd, Burnsville, MN 55306 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$150$150Aug 7, 2007Closed

Inspection 311118855 OPENED MAY 21, 2007Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 22, 2007

2960 & 2970 Judicial Rd, Burnsville, MN 55337 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309984086 OPENED MAR 20, 2006Closed

Planned · Partial · Safety · 2 employees at the site · Closed Mar 21, 2006

2900 West County Rd. 42, Burnsville, MN 55306 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309899698 OPENED FEB 23, 2006Closed

Planned · Complete · Safety · 1 employee at the site · Closed Feb 23, 2006

2900 W. County Rd. 42, Burnsville, MN 55306 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306763863 OPENED JUL 31, 2003Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 31, 2003

7287 161st St., Lakeville, MN 55044 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306759739 OPENED JUN 18, 2003Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jun 19, 2003

25 North Lake St, Forest Lake, MN 55025 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306759101 OPENED MAY 30, 2003Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 1, 2003

700 Grand Avenue, St Paul, MN 55105 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$450$315Jun 13, 2003Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$420Jun 13, 2003Closed

Inspection 301848412 OPENED JUN 2, 1997Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jun 2, 1997

3501 W. Co. Rd. 42, Burnsville, MN 55306 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 120429584 OPENED JUL 23, 1992Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 3, 1992

1526 Northway Drive, St Cloud, MN 56301 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 107781627 OPENED NOV 2, 1988Closed

Planned · No inspection · Safety · Closed Nov 21, 1988

3333 E. Cliff Road, Burnsville, MN 55337 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 2901106 OPENED JAN 14, 1986Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jan 22, 1986

1601 E. Hwy. 13, Burnsville, MN 55337 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.501 · Fall protection in construction

Other commercial and institutional building construction employers in Minnesota

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.