OSHA SearchOSHA records by employer

Eidd Construction Inc: OSHA inspections and violations

Wesley Chapel, Florida · Framing Contractors · NAICS 238130

2inspections
5citation items
$21,718current penalties
Nov 25, 2024last inspection

Eidd Construction Inc has 2 OSHA inspections on record in Florida, the first in 2024.

OSHA's last visit started on Nov 25, 2024 as a planned inspection, in Bradenton.

Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.

OSHA proposed $21,718 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. Eidd Construction Inc averages $10,859 over 2 cited inspections in that time.

Eidd Construction Inc: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Eidd Construction Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347900904 OPENED NOV 25, 2024Closed

Planned · Partial · Safety · 12 employees at the site · Closed Dec 3, 2025

14810 Sr 64 E, Bradenton, FL 34212 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$6,452$6,452Jan 3, 2025Final
Citation 1, item 2
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$6,452$6,452Jan 3, 2025Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$518$518Jan 3, 2025Final

Inspection 347531071 OPENED JUN 6, 2024Closed

Planned · Partial · Safety · 6 employees at the site · Closed Dec 3, 2025

6001 Wondering Willow Drive, Wesley Chapel, FL 33545 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$3,457$3,457Jul 2, 2024Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,839$4,839Jul 2, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(b)(2)

(2) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members shall be installed between the top edge of the guardrail system and the walking/working surface when there is no wall or parapet wall at least 21 inches (53 cm) high.

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.