Ejrm Construction, LLC: OSHA inspections and violations

Pearisburg, Virginia · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
2citation items
$889current penalties
Oct 21, 2024last inspection

OSHA inspectors have visited Ejrm Construction, LLC in Virginia one time.

It opened on Oct 21, 2024 as a planned inspection, in Pearisburg.

In all, OSHA issued 2 citation items: 2 serious.

The proposed penalties came to $1,270; today they stand at $889, 30% less.

The rule cited most here is 1926.405 (job-site wiring), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Ejrm Construction, LLC averages $889 across 1 cited inspection.

Ejrm Construction, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Ejrm Construction, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347829830 OPENED OCT 21, 2024Closed

Planned · Complete · Safety · 4 employees at the site · Closed Feb 12, 2025

120 N. Main St., Pearisburg, VA 24134 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$670$469Dec 20, 2024Final
Citation 1, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$600$420Dec 20, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.