Inspection 349134262 OPENED AUG 25, 2026Closed
1524 12 Th Ave Rd, Nampa, ID 83686 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Ekc, Inc. 9 times in Idaho since 1999.
The latest one began on Aug 25, 2026 as a planned inspection, in Nampa.
Those inspections ended with 6 citation items: 2 serious and 4 other-than-serious.
Penalties were first proposed at $6,519 and now stand at $4,019, 38% lower after settlements or reviews.
Sanitation comes up most often in these citations: 2 items under 1926.51.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Ekc, Inc. averages $4,019 (1 cited inspection).
Want to know if OSHA cites Ekc, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company1524 12 Th Ave Rd, Nampa, ID 83686 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1800 Bench Rd, Pocatello, ID 83201 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1777 S Curtis Rd., Boise, ID 83705 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1010 Main St, Boise, ID 83702 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(10) · Fall protection in construction |
Serious | $4,563 | $2,063 | Nov 7, 2017 | Final |
| Citation 1, item 1b 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $0 | $0 | Nov 7, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.1052(c)(1)(i) · Stairways in construction |
Other-than-serious | $1,956 | $1,956 | Nov 7, 2017 | Final |
| Citation 2, item 1a 29 CFR 1926.21(b)(4) · Construction safety training |
Other-than-serious | $0 | $0 | Nov 7, 2017 | Final |
| Citation 2, item 1b 29 CFR 1926.51(f)(1) · Sanitation |
Other-than-serious | $0 | $0 | Nov 7, 2017 | Final |
| Citation 2, item 1c 29 CFR 1926.51(h) · Sanitation |
Other-than-serious | $0 | $0 | Nov 7, 2017 | Final |
450 W. Mcgregor Dr, Boise, ID 83705 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
660 E. Water Tower, Meridian, ID 83642 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
975 E. Pine Avenue, Meridian, ID 83642 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4049 Eckert Rd., Boise, ID 83716 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
350 N. Milwaukee St, Boise, ID 83788 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.21(b)(4)
(4) In job site areas where harmful plants or animals are present, employees who may be exposed shall be instructed regarding the potential hazards, and how to avoid injury, and the first aid procedures to be used in the event of injury.
29 CFR 1926.501(b)(10)
(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.