OSHA SearchOSHA records by employer

Elaboraciones Fiesta: OSHA inspections and violations

Aguada, Puerto Rico · Tortilla Manufacturing · NAICS 311830

1inspections
5citation items
$448current penalties
Feb 5, 2019last inspection

OSHA inspectors have visited Elaboraciones Fiesta in Puerto Rico one time.

It opened on Feb 5, 2019 as a planned inspection, in Aguada.

In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

The proposed penalties came to $1,493; today they stand at $448, 70% less.

The rule cited most here is 1910.305 (electrical wiring methods), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. Elaboraciones Fiesta averages $448 across 1 cited inspection.

Elaboraciones Fiesta: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Elaboraciones Fiesta and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343765871 OPENED FEB 5, 2019Closed

Planned · Partial · Safety · 8 employees at the site · Closed Apr 15, 2019

Carr. 417 Km 1.8, Bo. Mal Paso, Aguada, PR 00602 · Tortilla Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.263(e)(1)(viii) · Bakery equipment
Serious$600$180Mar 4, 2019Final
Citation 1, item 2a
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$893$268Mar 4, 2019Final
Citation 1, item 2b
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$0$0Mar 4, 2019Final
Citation 2, item 1
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 4, 2019Final
Citation 2, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Mar 4, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.263 · Bakery equipment

29 CFR 1910.263(e)(1)(viii)

(viii) Every mixer shall be equipped with a full enclosure over the bowl which is closed at all times while the agitator is in motion. Only minor openings in this enclosure, such as ingredient doors, flour inlets, etc., each representing less than 1 1/2 square feet in area, shall be capable of being opened while the mixer is in operation.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

29 CFR 1910.305 · Electrical wiring methods

Other tortilla manufacturing employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.