OSHA SearchOSHA records by employer

Electrical Contractors Plus Inc: OSHA inspections and violations

Salt Lake City, Utah · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
2citation items
$1,500current penalties
Nov 9, 2015last inspection

Electrical Contractors Plus Inc has one OSHA inspection on record in Utah.

OSHA opened it on Nov 9, 2015 after a fatality or catastrophe, in Salt Lake City.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $1,500 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.501, fall protection in construction (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Electrical Contractors Plus Inc averages $1,500 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Electrical Contractors Plus Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Electrical Contractors Plus Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341047298 OPENED NOV 9, 2015Closed

Fatality or catastrophe · Partial · Safety · 2 employees at the site · Closed Feb 29, 2016

3929 S. 500 W., Salt Lake City, UT 84123 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 9, 2015 (fatal): Employee installing solar panel falls and is killed

On November 9, 2015, Employee #1, employed by an electrical contractor, was preparing to install a solar panel. As he picked up a panel, he fell to the concrete floor. Employee #1 was killed. The subsequent investigation revealed windy conditions at the time Employee #1 fell.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Jan 5, 2016Final
Citation 1, item 1b
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$0$0Jan 5, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

29 CFR 1926.501(b)(4)(i)

(4) Holes. (i) Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes.

Other electrical contractors and other wiring installation contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.