OSHA SearchOSHA records by employer

Electro-Metallics Inc: OSHA inspections and violations

Middletown, Ohio · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

2inspections
7citation items
$6,616current penalties
Oct 19, 2021last inspection

Electro-Metallics Inc has 2 OSHA inspections on record in Ohio, the first in 2011.

OSHA's last visit started on Oct 19, 2021 on a referral, in Middletown.

Across those inspections OSHA issued 7 citation items: 5 serious and 2 other-than-serious.

OSHA proposed $6,616 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.1200, hazard communication (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Electro-Metallics Inc averages $4,096 over 1 cited inspection in that time.

It reported 1 severe injury to OSHA since 2015.

Electro-Metallics Inc: OSHA citation items per year, 2011 to 2021
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

267employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Electro-Metallics Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345585756 OPENED OCT 19, 2021Closed

Referral · Partial · Health · 3 employees at the site · Closed Jan 4, 2022

3004 Lefferson Road, Middletown, OH 45044 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Incident on Oct 1, 2021: Two employees sustain chlorine burns, incompatible chemicals

At 2:45 p.m. on October 1, 2021, Employee #1 and Employee #2 who worked in production in an electroplating facility were draining a hydrochloric acid tank to replace the contents. The hose the employees were using had been previously used to move chlorine and had not been washed out afterward. When the employees began to use the hose to move the hydrochloric acid the acid and the chlorine reacted releasing chlorine gas. The employees were exposed resulting in chemical burns. Employee #1 was hospitalized for treatment due to inhaling the chlorine. Employee #2 received medical treatment but did not require hospitalization.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$4,096$4,096Nov 22, 2021Final
Citation 1, item 1b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Nov 22, 2021Final
Citation 1, item 1c
29 CFR 1910.1200(h)(2)(iii) · Hazard communication
Serious$0$0Nov 22, 2021Final

Inspection 315337931 OPENED FEB 28, 2011Closed

Planned · Partial · Health · 6 employees at the site · Closed Apr 15, 2011

3004 Lefferson Rd., Middletown, OH 45044 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$1,520$1,520Mar 23, 2011Closed
Citation 1, item 2
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$1,000$1,000Mar 23, 2011Closed
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 23, 2011Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 23, 2011Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Oct 1, 2021, Middletown: Hospitalization · chemical burns and corrosions, unspecified · multiple body parts, n.e.c.

Two employees were cleaning a hose that contained hydrochloric acid. After rinsing the hose, it was placed in a tank with bleach. Hydrochloric acid remaining on the hose reacted with the bleach, exposing the employees to chlorine gas that made it difficult to breathe. One employee was hospitalized for inhalation chemical burns.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.132 · Personal protective equipment, general requirements

Other electroplating, plating, polishing, anodizing, and coloring employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.