OSHA SearchOSHA records by employer

Elevated Drywall: OSHA inspections and violations

Moroni, Utah · Drywall and Insulation Contractors · NAICS 238310

1inspections
5citation items
$2,100current penalties
Jul 29, 2024last inspection

OSHA has inspected Elevated Drywall once in Utah.

The inspection began on Jul 29, 2024 on a referral, in Moroni.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $2,100 and still stand at $2,100.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Elevated Drywall averages $2,100 (1 cited inspection).

Elevated Drywall also files yearly injury logs with OSHA, summarized below.

Elevated Drywall: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Elevated Drywall again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347657447 OPENED JUL 29, 2024Closed

Referral · Partial · Safety · 2 employees at the site · Closed Dec 18, 2024

630 East 100 South, Moroni, UT 84646 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 27, 2024Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Sep 27, 2024Final
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Sep 27, 2024Final
Citation 1, item 1d
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$0$0Sep 27, 2024Final
Citation 1, item 2
29 CFR 1926.454(a) · Scaffold training
Serious$2,100$2,100Sep 27, 2024Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Moroni site logged 0 recordable injuries or illnesses among about 14 workers: 0.0 per 100 full-time workers, against a median of 2.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Elevated Drywall
Moroni · 2023
14 000.02.3

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other drywall and insulation contractors employers in Utah

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.