OSHA SearchOSHA records by employer

Eliseo Marin LLC: OSHA inspections and violations

Blackshear, Georgia · Framing Contractors · NAICS 238130

1inspections
5citation items
$7,378current penalties
Apr 30, 2026last inspection

OSHA has inspected Eliseo Marin LLC once in Georgia.

The inspection began on Apr 30, 2026, in Blackshear; the case is still open.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $7,378 and still stand at $7,378.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Eliseo Marin LLC averages $7,378 (1 cited inspection).

Eliseo Marin LLC: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

146employers cited

25 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Eliseo Marin LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348912361 OPENED APR 30, 2026Open

Inspection · Partial · Safety · 5 employees at the site · Open

3005 Us Hwy 84, Blackshear, GA 31516 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$2,270$2,270Jul 28, 2026Final
Citation 1, item 1b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Jul 28, 2026Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,838$2,838Jul 28, 2026Final
Citation 1, item 2b
29 CFR 1926.451(f)(5) · Scaffolds, general requirements
Serious$0$0Jul 28, 2026Final
Citation 1, item 3
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$2,270$2,270Jul 28, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(b)(5)(ii)

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.