Elite Construction Design, Inc.: OSHA inspections and violations

Denver, Colorado · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

3inspections
7citation items
$3,996current penalties
Aug 11, 2015last inspection

OSHA has inspected Elite Construction Design, Inc. 3 times in Colorado since 2011.

The latest one began on Aug 11, 2015 as a planned inspection, in Denver.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $6,660 and now stand at $3,996, 40% lower after settlements or reviews.

Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Elite Construction Design, Inc. averages $2,160 (1 cited inspection).

Elite Construction Design, Inc.: OSHA citation items per year, 2011 to 2015
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

132employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Elite Construction Design, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340878974 OPENED AUG 11, 2015Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 23, 2016

3835 & 3837 W. 38th Ave., Denver, CO 80212 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$2,000$1,200Feb 1, 2016Final
Citation 1, item 2
29 CFR 1926.1052(c)(1) · Stairways in construction
Serious$1,600$960Feb 1, 2016Final

Inspection 335937603 OPENED JUL 18, 2012Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Sep 12, 2012

4481 & 4491 Winona Ct., Denver, CO 80211 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 330981713 OPENED AUG 27, 2011Closed

Planned · Complete · Safety · 2 employees at the site · Closed Oct 14, 2011

3930 Utica Street, Denver, CO 80212 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$1,530$918Sep 1, 2011Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Sep 1, 2011Final
Citation 1, item 1c
29 CFR 1926.405(d) · Job-site wiring
Serious$0$0Sep 1, 2011Final
Citation 1, item 1d
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$0$0Sep 1, 2011Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,530$918Sep 1, 2011Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)

(1) Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.