OSHA SearchOSHA records by employer

Elite Roofing: OSHA inspections and violations

Colorado Springs, Colorado · Roofing Contractors · NAICS 238160

4inspections
4citation items
$11,474current penalties
Aug 18, 2020last inspection

Since 2015, OSHA inspectors have visited Elite Roofing in Colorado 4 times.

The most recent inspection opened on Aug 18, 2020 as a planned inspection, in Fountain.

In all, OSHA issued 4 citation items: 2 serious, 1 repeat and 1 other-than-serious.

The proposed penalties came to $15,713; today they stand at $11,474, 27% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Elite Roofing averages $3,825 across 3 cited inspections.

Elite Roofing: OSHA citation items per year, 2015 to 2020
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

25 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Elite Roofing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344902788 OPENED AUG 18, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 16, 2020

10539 Traders Parkway, Fountain, CO 80817 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,735$900Sep 1, 2020Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$6,362$4,000Sep 1, 2020Final

Inspection 344453949 OPENED NOV 18, 2019Closed

Complaint · Partial · Safety · 20 employees at the site · Closed Jan 9, 2020

5440 Ward Road, Arvada, CO 80002 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Other-than-serious$4,774$4,774Nov 29, 2019Final

Inspection 344223508 OPENED AUG 10, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 5, 2019

8244 Diorite Dr, Colorado Springs, CO 80938 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,842$1,800Aug 28, 2019Final

Inspection 340710755 OPENED JUN 15, 2015Closed

Unprogrammed related · Partial · Safety · 6 employees at the site · Closed Jun 26, 2015

6451 Maroon Mesa Drive, Colorado Springs, CO 80902 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

Other roofing contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.