Ellis Electrical Contractors, LLC.: OSHA inspections and violations

Atlanta, Georgia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
3citation items
$3,421current penalties
Jul 26, 2016last inspection

Ellis Electrical Contractors, LLC. has one OSHA inspection on record in Georgia.

OSHA opened it on Jul 26, 2016 as part of a related case, in Atlanta.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $5,701 in penalties. After settlements and reviews the total is $3,421, down 40%.

Most often, OSHA cited 1926.405, job-site wiring (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Ellis Electrical Contractors, LLC. averages $3,421 over 1 cited inspection in that time.

Ellis Electrical Contractors, LLC.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Ellis Electrical Contractors, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341654283 OPENED JUL 26, 2016Closed

Unprogrammed related · Partial · Safety · 25 employees at the site · Closed May 16, 2017

1032 Metropolitian Parkway, Atlanta, GA 30342 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii)(c) · Job-site wiring
Serious$3,563$2,138Sep 13, 2016Final
Citation 1, item 2a
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$2,138$1,283Sep 13, 2016Final
Citation 1, item 2b
29 CFR 1926.405(a)(2)(ii)(j) · Job-site wiring
Serious$0$0Sep 13, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(c)

(C) Receptacles shall be of the grounding type. Unless installed in a complete metallic raceway, each branch circuit shall contain a separate equipment grounding conductor, and all receptacles shall be electrically connected to the grounding conductor. Receptacles for uses other than temporary lighting shall not be installed on branch circuits which supply temporary lighting. Receptacles shall not be connected to the same ungrounded conductor of multiwire circuits which supply temporary lighting.

29 CFR 1926.405(a)(2)(ii)(f)

(F) Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.

29 CFR 1926.405(a)(2)(ii)(j)

(J) Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage.