Inspection 341090363 OPENED OCT 1, 2015Closed
Slater Drive, Elmwood Park, NJ 07407 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Elmwood Park, New Jersey · Sewage Treatment Facilities · NAICS 221320
Elmwood Park DPW - Sewer has 3 OSHA inspections on record in New Jersey, the first in 2015.
OSHA's last visit started on Oct 1, 2015 to follow up on an earlier case, in Elmwood Park.
Across those inspections OSHA issued 17 citation items: 7 serious and 10 other-than-serious.
OSHA proposed $43,700 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.157, portable fire extinguishers (3 items).
For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Elmwood Park DPW - Sewer averages $21,850 over 2 cited inspections in that time.
New Jersey · latest 90 days of OSHA records
270employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Elmwood Park DPW - Sewer and get notified the morning OSHA posts a new citation for it.
Watch this companySlater Drive, Elmwood Park, NJ 07407 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Slater Drive, Elmwood Park, NJ 07407 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(6) · Exit routes |
Serious | $6,300 | $6,300 | Jul 28, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.38(b) · Emergency action plans |
Other-than-serious | $900 | $900 | Jul 28, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.39(b) · Fire prevention plans |
Other-than-serious | $900 | $900 | Jul 28, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $900 | $900 | Jul 28, 2015 | Final |
| Citation 2, item 4 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Other-than-serious | $900 | $900 | Jul 28, 2015 | Final |
| Citation 2, item 5 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $900 | $900 | Jul 28, 2015 | Final |
Slater Drive, Elmwood Park, NJ 07407 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.26(c)(2)(vii) · Portable metal ladders |
Serious | $4,900 | $4,900 | Jul 31, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.146(c)(5)(ii)(b) · Permit-required confined spaces |
Serious | $4,900 | $4,900 | Jul 31, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Serious | $4,900 | $4,900 | Jul 31, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $4,900 | $4,900 | Jul 31, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Serious | $4,900 | $4,900 | Jul 31, 2015 | Final |
| Citation 1, item 6 29 CFR 1910.305(a)(2)(i) · Electrical wiring methods |
Serious | $4,900 | $4,900 | Jul 31, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Other-than-serious | $700 | $700 | Jul 31, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.146(c)(3) · Permit-required confined spaces |
Other-than-serious | $700 | $700 | Jul 31, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Other-than-serious | $700 | $700 | Jul 31, 2015 | Final |
| Citation 2, item 4 29 CFR 1910.157(e)(3) · Portable fire extinguishers |
Other-than-serious | $700 | $700 | Jul 31, 2015 | Final |
| Citation 2, item 5 29 CFR 1910.179(j)(1)(ii)(b) · Overhead and gantry cranes |
Other-than-serious | $700 | $700 | Jul 31, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.132(d)(2)
(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.
29 CFR 1910.146(c)(2)
(2) If the workplace contains permit spaces, the employer shall inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces.
29 CFR 1910.146(c)(3)
(3) If the employer decides that its employees will not enter permit spaces, the employer shall take effective measures to prevent its employees from entering the permit spaces and shall comply with paragraphs (c)(1), (c)(2), (c)(6), and (c)(8) of this section.
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.