Emerson Automation Solutions: OSHA inspections and violations

Stephenville, Texas · All Other Miscellaneous Electrical Equipment and Component Manufacturing · NAICS 335999

1inspections
2citation items
$9,313current penalties
Oct 19, 2017last inspection

Emerson Automation Solutions has one OSHA inspection on record in Texas.

OSHA opened it on Oct 19, 2017 on a referral, in Stephenville.

From that inspection OSHA issued 2 citation items: 2 other-than-serious.

OSHA proposed $23,282 in penalties. After settlements and reviews the total is $9,313, down 60%.

Most often, OSHA cited 1910.147, lockout/tagout (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Emerson Automation Solutions averages $9,313 over 1 cited inspection in that time.

Emerson Automation Solutions: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Emerson Automation Solutions and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342720448 OPENED OCT 19, 2017Closed

Referral · Partial · Safety · 140 employees at the site · Closed Jul 6, 2018

2150 W. South Loop, Stephenville, TX 76401 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Oct 13, 2017: Employee's hand is crushed when weld machine cycles

At 2:00 p.m. on October 13, 2017, Employee #1 was tightening a bolt on the weld machine. The employee put one hand on the right side of the dual controls, and his baseball cap activated the left side, causing the machine to cycle. His left hand was crushed and lacerated. Employee #1 was hospitalized for treatment. for treatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$11,641$4,656Mar 19, 2018Final
Citation 1, item 2
29 CFR 1910.147(d)(4)(i) · Lockout/tagout
Other-than-serious$11,641$4,656Mar 19, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(d)(4)(i)

(4) Lockout or tagout device application. (i) Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.

Other all other miscellaneous electrical equipment and component manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.