OSHA SearchOSHA records by employer

Emilio Velasquez Roofing and Construction: OSHA inspections and violations

Cincinnati, Ohio · Roofing Contractors · NAICS 238160

1inspections
3citation items
$2,000current penalties
Jun 24, 2025last inspection

OSHA has inspected Emilio Velasquez Roofing and Construction once in Ohio.

The inspection began on Jun 24, 2025 as a planned inspection, in Cincinnati.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $14,895 and now stand at $2,000, 87% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Emilio Velasquez Roofing and Construction averages $2,000 (1 cited inspection).

Emilio Velasquez Roofing and Construction: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

257employers cited

65 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Emilio Velasquez Roofing and Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348328014 OPENED JUN 24, 2025Closed

Planned · Partial · Health · 4 employees at the site · Closed Aug 4, 2026

4182 Vine St., Cincinnati, OH 45217 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$4,965$0Aug 26, 2025Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$4,965$2,000Aug 26, 2025Final
Citation 1, item 1c
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$4,965$0Aug 26, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

Other roofing contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.