OSHA SearchOSHA records by employer

Empcol, Inc.: OSHA inspections and violations

Denver, Colorado · Residential Remodelers · NAICS 236118

2inspections
8citation items
$16,552current penalties
Dec 12, 2024last inspection

OSHA has inspected Empcol, Inc. 2 times in Colorado since 2019.

The latest one began on Dec 12, 2024 after a complaint, in Aurora.

Those inspections ended with 8 citation items: 8 other-than-serious.

Penalties were first proposed at $16,552 and still stand at $16,552.

Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Empcol, Inc. averages $16,552 (1 cited inspection).

Empcol, Inc.: OSHA citation items per year, 2019 to 2024
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

135employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Empcol, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347936338 OPENED DEC 12, 2024Closed

Complaint · Partial · Safety · 37 employees at the site · Closed Jun 4, 2025

2095 South Pontiac Drive, Aurora, CO 80015 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$8,276$8,276May 6, 2025Final
Citation 1, item 1b
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Other-than-serious$0$0May 6, 2025Final
Citation 1, item 1c
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Other-than-serious$0$0May 6, 2025Final
Citation 1, item 1d
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Other-than-serious$0$0May 6, 2025Final
Citation 1, item 1e
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$0$0May 6, 2025Final
Citation 1, item 1f
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Other-than-serious$0$0May 6, 2025Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$8,276$8,276May 6, 2025Final
Citation 2, item 1
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$0$0May 6, 2025Final

Inspection 343978854 OPENED MAY 2, 2019Closed

Planned · Partial · Safety · 1 employee at the site · Closed May 16, 2019

1150 Inca St., Denver, CO 80204 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

Other residential remodelers employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.