OSHA SearchOSHA records by employer

Ena Maintenance LLC dba Ena Weathershield: OSHA inspections and violations

River Grove, Illinois · Roofing Contractors · NAICS 238160

1inspections
2citation items
$7,944current penalties
Sep 2, 2025last inspection

Ena Maintenance LLC dba Ena Weathershield has one OSHA inspection on record in Illinois.

OSHA opened it on Sep 2, 2025 as a planned inspection, in River Grove, and the case has not closed yet.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $7,944 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Ena Maintenance LLC dba Ena Weathershield averages $7,944 over 1 cited inspection in that time.

Ena Maintenance LLC dba Ena Weathershield: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

157 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Ena Maintenance LLC dba Ena Weathershield and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348477951 OPENED SEP 2, 2025Open

Planned · Partial · Safety · 5 employees at the site · Open

8347 W. Grand Ave, River Grove, IL 60171 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$3,972$3,972Jan 15, 2026Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,972$3,972Jan 15, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.