OSHA SearchOSHA records by employer

Enerfab Process Solutions & Fabricated Products, Inc.: OSHA inspections and violations

Wilmington, Delaware · Metal Tank (Heavy Gauge) Manufacturing · NAICS 332420

2inspections
5citation items
$276,402current penalties
Jan 23, 2019last inspection

OSHA has inspected Enerfab Process Solutions & Fabricated Products, Inc. 2 times in Delaware since 2019.

The latest one began on Jan 23, 2019 on a referral, in Wilmington.

Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $291,716 and now stand at $276,402, 5% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Enerfab Process Solutions & Fabricated Products, Inc. averages $276,402 (1 cited inspection).

1 inspection on this page followed a fatal incident.

Enerfab Process Solutions & Fabricated Products, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Delaware · latest 90 days of OSHA records

32employers cited

Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Delaware

Checking a subcontractor, a client or your own company? Watch Enerfab Process Solutions & Fabricated Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343730859 OPENED JAN 23, 2019Closed

Referral · Partial · Health · 275 employees at the site · Closed Mar 29, 2021

1000 Ferry Road, Wilmington, DE 19801 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343730727 OPENED JAN 10, 2019Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Apr 5, 2021

1000 Ferry Road, Wilmington, DE 19801 · Metal Tank (Heavy Gauge) Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 9, 2019 (fatal): Employee is killed in fall from scaffold during tank cleanin

At 1:45 p.m. on January 9, 2019, an employee was painting the inside of a large above ground storage tank. The employee fell from mast climbing a scaffold to the bottom of the tank. The employee sustained multiple fractures to the torso, legs, and head, killing him.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.407(b) · Hazardous (classified) locations
Other-than-serious$13,260$402Jul 8, 2019Final
Citation 2, item 1a
29 CFR 1926.451(g)(1)(ii) · Scaffolds, general requirements
Serious$132,598$276,000Jul 8, 2019Final
Citation 2, item 1b
29 CFR 1926.451(g)(3) · Scaffolds, general requirements
Serious$0$0Jul 8, 2019Final
Citation 2, item 1c
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$132,598$0Jul 8, 2019Final
Citation 2, item 1d
29 CFR 1926.451(d)(3)(i) · Scaffolds, general requirements
Serious$13,260$0Jul 8, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.407 · Hazardous (classified) locations

29 CFR 1926.407(b)

(b) Electrical installations. Equipment, wiring methods, and installations of equipment in hazardous (classified) locations shall be approved as intrinsically safe or approved for the hazardous (classified) location or safe for the hazardous (classified) location. Requirements for each of these options are as follows:

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(d)(3)(i)

(i) Before the scaffold is used, direct connections shall be evaluated by a competent person who shall confirm, based on the evaluation, that the supporting surfaces are capable of supporting the loads to be imposed. In addition, masons' multi-point adjustable suspension scaffold connections shall be designed by an engineer experienced in such scaffold design.

29 CFR 1926.451(g)(1)(ii)

(ii) Each employee on a single-point or two-point adjustable suspension scaffold shall be protected by both a personal fall arrest system and guardrail system;

Other metal tank (heavy gauge) manufacturing employers in Delaware

Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.