OSHA SearchOSHA records by employer

Energizer Manufacturing, Inc.: OSHA inspections and violations

Fennimore, Wisconsin · Primary Battery Manufacturing · NAICS 335912

1inspections
1citation items
$7,814current penalties
Jan 24, 2019last inspection

OSHA inspectors have visited Energizer Manufacturing, Inc. in Wisconsin one time.

It opened on Jan 24, 2019 on a referral, in Fennimore.

In all, OSHA issued 1 citation item: 1 serious.

The proposed penalties came to $10,419; today they stand at $7,814, 25% less.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Energizer Manufacturing, Inc. averages $7,814 across 1 cited inspection.

Energizer Manufacturing, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Energizer Manufacturing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Energizer Manufacturing, Inc. at 2 sites in 2 states. Together they've had 2 inspections and $14,014 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 2 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 343735874 OPENED JAN 24, 2019Closed

Referral · Partial · Safety · 275 employees at the site · Closed Jun 25, 2019

100 Rayovac Drive, Fennimore, WI 53809 · Primary Battery Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 16, 2019: Employee amputates finger while adjusting air nozzle on mach

At 7:45 a.m. on January 16, 2019, Employee #1 was adjusting the air nozzle on the machine. The employee opened a door on the machine to adjust air nozzles on a nail bowl which controlled the speed of battery nails coming out of the machine. The employee reached into the machine to adjust the air nozzles which were located next to a grinder belt and pulley. While doing so, the employee got her right index finger caught between the grinder belt and pulley. The employee was wearing gloves at the time of the incident. The employee pulled her hand free from the machine and the employer called 911. The employee sustained an amputation to the right index finger. The employee was working alone at the time of the incident and there were no witnesses. The employee was hospitalized. was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$10,419$7,814May 23, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

Other primary battery manufacturing employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.