OSHA SearchOSHA records by employer

Enrique Masonry: OSHA inspections and violations

Southaven, Mississippi · Masonry Contractors · NAICS 238140

1inspections
3citation items
$14,652current penalties
Jun 17, 2020last inspection

OSHA has inspected Enrique Masonry once in Mississippi.

The inspection began on Jun 17, 2020 as a planned inspection, in Southaven.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $14,652 and still stand at $14,652.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Enrique Masonry averages $14,652 (1 cited inspection).

Enrique Masonry: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

15employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Enrique Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344798822 OPENED JUN 17, 2020Closed

Planned · Complete · Safety · 12 employees at the site · Closed Apr 6, 2023

2911 Central Parkway, Southaven, MS 38672 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,856$3,856Jul 16, 2020Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$5,398$5,398Jul 16, 2020Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$5,398$5,398Jul 16, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

Other masonry contractors employers in Mississippi