OSHA SearchOSHA records by employer

Ernest Thompson Furniture: OSHA inspections and violations

Albuquerque, New Mexico · Nonupholstered Wood Household Furniture Manufacturing · NAICS 337122

3inspections
35citation items
$830current penalties
Oct 8, 2015last inspection

Ernest Thompson Furniture has 3 OSHA inspections on record in New Mexico, the first in 1989.

OSHA's last visit started on Oct 8, 2015 on a referral, in Albuquerque.

Across those inspections OSHA issued 35 citation items: 16 serious and 19 other-than-serious.

OSHA proposed $5,555 in penalties. After settlements and reviews the total is $830, down 85%.

Most often, OSHA cited 1910.95, noise (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Ernest Thompson Furniture averages $500 over 1 cited inspection in that time.

Ernest Thompson Furniture: OSHA citation items per year, 1989 to 2015
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

32employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Ernest Thompson Furniture and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341031169 OPENED OCT 8, 2015Closed

Referral · Complete · Safety · 36 employees at the site · Closed Feb 29, 2016

4531 Osuna Road Ne, Albuquerque, NM 87109 · Nonupholstered Wood Household Furniture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$875$500Nov 10, 2015Final

Inspection 115149999 OPENED OCT 14, 1992Closed

Complaint · Complete · Safety · 49 employees at the site · Closed Sep 25, 1993

2618 Coors Sw, Albuquerque, NM 87121 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$2,000$200Mar 4, 1993Final
Citation 1, item 1b Serious$0$0Mar 4, 1993Final
Citation 1, item 1c Serious$0$0Mar 4, 1993Final
Citation 1, item 1d Serious$0$0Mar 4, 1993Final
Citation 1, item 1e Serious$0$0Mar 4, 1993Final
Citation 1, item 1f Serious$0$0Mar 4, 1993Final
Citation 1, item 2a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$800$80Mar 4, 1993Final
Citation 1, item 2b
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$0$0Mar 4, 1993Final
Citation 1, item 2c
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Mar 4, 1993Final
Citation 1, item 2d
29 CFR 1910.106(eii) · Flammable liquids
Serious$0$0Mar 4, 1993Final
Citation 1, item 4
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$1,000$0Mar 4, 1993Final
Citation 2, item 1 Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 3
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 4
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 5
29 CFR 1910.134(b)(1) · Respiratory protection
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 6
29 CFR 1910.134(b)(3) · Respiratory protection
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 7
29 CFR 1910.134(b)(6) · Respiratory protection
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 8
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 4, 1993Closed
Citation 2, item 10
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 4, 1993Closed

Inspection 108500075 OPENED NOV 30, 1989Closed

Complaint · Complete · Safety · 38 employees at the site · Closed Jun 26, 1990

2618 Coors Sw, Albuquerque, NM 87121 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(a)(9) · Woodworking machinery
Other-than-serious$200$0Mar 7, 1990Final
Citation 1, item 3
29 CFR 1910.213(g)(2) · Woodworking machinery
Other-than-serious$200$0Mar 7, 1990Final
Citation 1, item 4a
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Serious$160$20Mar 7, 1990Final
Citation 1, item 4b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Mar 7, 1990Final
Citation 1, item 5
29 CFR 1910.219(c)(4)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$120$0Mar 7, 1990Final
Citation 1, item 6a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$120$20Mar 7, 1990Final
Citation 1, item 6b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 7, 1990Final
Citation 1, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$80$10Mar 7, 1990Final
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Mar 7, 1990Closed
Citation 2, item 2
29 CFR 1020000 A
Other-than-serious$0$0Mar 7, 1990Closed
Citation 2, item 3
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 7, 1990Closed
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 7, 1990Closed
Citation 2, item 5
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Mar 7, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other nonupholstered wood household furniture manufacturing employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.